The thermistor assembly is installed in the front part of the condenser to detect the ambient temperature and control the air conditioner. The thermistor assembly is connected to the combination meter assembly and detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The thermistor assembly sends a signal to the air conditioning control assembly via the combination meter assembly. The resistance of the thermistor assembly changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The combination meter assembly applies a voltage (5 V) to the thermistor assembly and reads voltage changes as changes in the resistance of the thermistor assembly. The combination meter assembly sends the read signal to the air conditioning control assembly via CAN communication.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1432/22 | Open in ambient temperature sensor circuit | ·
Ambient temperature sensor (thermistor assembly) ·
Harness or connector between ambient temperature sensor (thermistor assembly) and air conditioning control assembly ·
Air conditioning control assembly |
| B1433/-22 | Short in ambient temperature Sensor circuit | ·
Ambient temperature sensor (thermistor assembly) ·
Harness or connector between ambient temperature sensor (thermistor assembly) and air conditioning control assembly ·
Air conditioning control assembly |
The heater and air conditioning system uses the CAN communication system. First, carry out the check of CAN communication system in accordance with the "HOW TO PROCEED WITH TROUBLESHOOTING", and confirm that there are no problems with the communications system before proceeding with troubleshooting.
Errors with the combination meter assembly may affect this DTC. Prior to carrying out an inspection, inspect "Meter and gauge system" DTCs, and confirm that the combination meter assembly is normal.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Ambient Temp Sensor
(Ambi Temp Sens) |
Ambient temperature sensor (thermistor assembly) /
Min: -40.00°C (-40.00°F) Max: 80.00°C (176.00°F) |
Actual ambient temperature displayed | - |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to the DTC) | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| NG | C |
A
B
C
Check the DTCs (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)>CUSTOMIZE PARAMETERS)
DTC is not output.
OK
NG
Remove the ambient temperature sensor (thermistor assembly) (See page Vehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>REMOVAL).
Inspect the ambient temperature sensor (thermistor assembly) (See page Vehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>INSPECTION).
OK
NG
Disconnect the D7 conditioning meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A48-1 - D7-24(TAM) | Always | Below 1 Ω |
| A48-2 - D7-25(SG-) | Always | Below 1 Ω |
| A48-1 - Body ground | Always | 10 kΩ or higher |
| A48-2 - Body ground | Always | 10 kΩ or higher |
OK
NG