Home › Vehicle Interior › HEATING / AIR CONDITIONING › REFRIGERANT(for HFC-134a(R134a))
RM2090E _58 Vehicle Interior _060704 HEATING / AIR CONDITIONING _0297736 REFRIGERANT(for HFC-134a(R134a)) A

HEATING / AIR CONDITIONING  REFRIGERANT(for HFC-134a(R134a))  REPLACEMENT  


PROCEDURE

Hide 1.RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

a.

Start the engine.


b.

Operate the cooler compressor under the conditions shown below:

Item Condition
Engine Speed Idling
Operating Time 3 minutes or more
A/C Switch Status On
Blower Switch Status HI
Set Temperature MAX COOL

This causes most of the compressor oil from the various components of the A/C system to collect in the A/C compressor.

NOTICE:

It is not necessary to operate the cooler compressor if the A/C does not operate because of compressor lock, etc.



c.

Stop the engine.


d.

Recover the refrigerant from the A/C system using a refrigerant recovery unit.

HINT:

Use the refrigerant recovery unit in accordance with the manufacturer's instruction manual.



Hide 2.CHARGE REFRIGERANT

I100449E18
0.438,2.896 2.656,3.083 2.219,0.188 10 false Check and repair connection portion 1.198,3.906 3.385,4.104 2.188,0.198 10 false Gauge indicates abnormal pressure 3.781,0.448 4.813,0.625 1.031,0.177 10 false Start evacuation 3.76,2.073 5.031,2.26 1.271,0.188 10 false Suspend evacuation 3.792,3.708 4.99,3.906 1.198,0.198 10 false Check airtightness 3.771,5.365 4.896,5.552 1.125,0.188 10 false Charge refrigerant 3.76,6.969 5.146,7.177 1.385,0.208 10 false Check for gas leakage 5.323,4.094 6.792,4.448 1.469,0.354 10 false Gauge indicates normal pressure 5.24,0.833 7.042,1.365 1.802,0.531 10 false Evacuate until the pressure is 0.1 MPa (750 mmHg, 30 in. Hg) 5.281,2.458 7.083,2.979 1.802,0.521 10 false Leave to stand for 5 minutes (Check that the pressure has not changed after 5 minutes.)

HINT:

Charge refrigerant in accordance with the equipment manual.


a.

Perform vacuum purging using a vacuum pump.


b.

Charge refrigerant HFC-134a (R134a).

SST
09985-20010  (09985-02130, 09985-02150, 09985-02090, 09985-02110, 09985-02010, 09985-02050, 09985-02060, 09985-02070)

Standard:

390 +/-50 g (13.8 +/-1.8 oz)


E209507E14
4.531,1.75 4.792,0.969 4.792,0.969 4.885,0.969 false 3.125,1.792 3.375,1.792 3.375,1.792 3.521,1.896 false 2.615,0.313 2.792,0.5 0.177,0.188 10 false *a 3.917,0.729 4.094,0.917 0.177,0.188 10 false *b 4.906,0.885 5.073,1.052 0.167,0.167 10 false *c 5.792,1.531 5.958,1.698 0.167,0.167 10 false *e 2.958,1.708 3.135,1.875 0.177,0.167 10 false *d 1.667,3.313 1.854,3.51 0.188,0.198 10 false *g 3.781,3.104 3.958,3.281 0.177,0.177 10 false *h 0.813,1.531 0.979,1.708 0.167,0.177 10 false *f 3.927,2.292 5.125,2.469 1.198,0.177 10 false +/-50 g (+/-1.8 oz)

Text in Illustration
*a Amount to be charged *b Charge 100 g (3.53 oz)
*c Mean value in proper range *d Point where bubbles disappear
*e Overcharged *f Pressure
*g Sub-cool system *h Refrigerant amount

NOTICE:

Do not operate the cooler compressor before charging refrigerant as the cooler compressor will not work properly without any refrigerant, and will overheat.



Hide 3.WARM UP ENGINE

a.

Warm up the engine at less than 2000 rpm for 2 minutes or more after charging the refrigerant.

NOTICE:

Be sure to warm up the compressor by turning the A/C switch on after removing and installing the cooler refrigerant lines (including the compressor) to prevent damage to the compressor.



Hide 4.CHECK FOR REFRIGERANT GAS LEAK

a.

After recharging the refrigerant, check for refrigerant gas leakage using a halogen leak detector.

i.

Perform the operation observing the following instructions:

·

Stop the engine.

·

Secure good ventilation (the halogen leak detector may react to volatile gases other than refrigerant, such as evaporated gasoline or exhaust gas).

·

Repeat the test 2 or 3 times.

·

Make sure that some refrigerant remains in the refrigeration system.

HINT:

When the compressor is off: approximately 392 to 588 kPa (4.0 to 6.0 kgf/cm2, 57 to 85 psi).




ii.
E225096E01
0.075,0.049 0.273,0.239 0.198,0.191 10 *a 3.152,0.246 3.350,0.437 0.198,0.191 10 *1 2.808,1.467 2.808,0.345 2.808,0.345 3.113,0.345 false

Using a halogen leak detector, check the refrigerant line for leakage.


iii.

If a gas leak is not detected from the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the halogen leak detector sensor into the unit and check for gas leakage.


iv.

Disconnect the pressure switch connector and wait for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and check for gas leakage.

Text in Illustration
*1 Halogen Leak Detector
*a Check for Leakage