1.INSPECT AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY
Check the wire harness.
Disconnect the air conditioner tube and accessory assembly connector.
Using an ohmmeter, measure the resistance of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 - Body ground | Always | Below 1 Ω |
| 2 - 4 | Ignition switch ON | Below 1 Ω |
| *a | Component without harness connected
(air conditioner tube and accessory assembly) |
Check the air conditioning pressure sensor.
Install a manifold gauge set.
Apply pressure on the sensor as indicated in the table below, and check the resistance between the terminals.
| *1 | Sensor Part |
for HFC-134a (R134a):
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 4 | 0 kPa (No Pressure applied) | 10 kΩ or higher |
| 1 - 4 | 1520 kPa (15.5 kgf/cm2, 221 psi) | Below 1 Ω |
| 2 - 3 | 0 kPa (No Pressure applied) | 10 kΩ or higher |
| 2 - 3 | 22.5 kPa (0.23 kgf/cm2, 33.0 psi) or more and below 3140 kPa (32 kgf/cm2, 455 psi) | Below 1 Ω |
| 2 - 3 | 3140 kPa (32 kgf/cm2, 455 psi) or more | 10 kΩ or higher |
for HFO-1234yf (R1234yf):
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 4 | 0 kPa (No Pressure applied) | 10 kΩ or higher |
| 1 - 4 | 1520 kPa (15.5 kgf/cm2, 221 psi) | Below 1 Ω |
| 2 - 3 | 0 kPa (No Pressure applied) | 10 kΩ or higher |
| 2 - 3 | 248 kPa (2.53 kgf/cm2, 36.5 psi) or more and below 2980 kPa (30.4 kgf/cm2, 438 psi) | Below 1 Ω |
| 2 - 3 | 2980 kPa (30.4 kgf/cm2, 438 psi) or more | 10 kΩ or higher |