1.INSPECT HEATER RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied | 10 kΩ or higher |
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the heater relay.
2.INSPECT HEATER BLOWER MOTOR RELAY ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage not applied | Below 1 Ω |
| 3 - 4 | Battery voltage applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage not applied | 10 kΩ or higher |
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the heater blower motor relay assembly.