81980
1.INSPECT TURN SIGNAL FLASHER ASSEMBLY
Disconnect the D61 turn signal flasher assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D61-4 (+B) - Body ground | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |
| D61-1 (IG) - Body ground | Always | 11 to 14 V |
| *a | Front view of wire harness connector
(to Turn Signal Flasher Assembly) |
If the result is not as specified, repair or replace the wire harness or connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| D61-7 (GND) - Body ground | Always | Below 1 Ω |
If the result is not as specified, repair or replace the wire harness or connector.
Reconnect the D61 turn signal flasher assembly connector.
Measure the voltage according to the valve(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| D61-6 (ER) - Body ground | Turn signal switch in RH position OFF to ON | 9 V or higher to below 1 V |
| D61-5 (EL) - Body ground | Turn signal switch in LH position OFF to ON | 9 V or higher to below 1 V |
| D61-8 (EHW) - Body ground | Hazard warning switch OFF to ON | 9 V or higher to below 1 V |
| D61-2 (LR) - Body ground | Turn signal switch in RH position OFF to ON | Below 1 V to 9 V (60 to 120 times per minute) |
| D61-3 (LL) - Body ground | Turn signal switch in LH position OFF to ON | Below 1 V to 9 V (60 to 120 times per minute) |
| D61-2 (LR) - Body ground | Hazard warning switch OFF to ON | Below 1 V to 9 V (60 to 120 times per minute) |
| D61-3 (LL) - Body ground | Hazard warning switch OFF to ON | Below 1 V to 9 V (60 to 120 times per minute) |
| *a | Component with harness connected
(Turn Signal Flasher Assembly) |
If the result is not as specified, the turn signal flasher assembly may have a malfunction.