DATA LIST
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed.
Reading the Data List information early in troubleshooting is one way to save diagnostic time.
In the table below, the values listed under Normal Condition are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Warm up the engine.
Turn the ignition switch off.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Data List.
Check the values by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Battery Voltage | Battery voltage:
Min.: 0 V, Max.: 65.535 V |
12.2 to 14.6 V: Idling | When the battery voltage is below 11 V, other systems may be affected.
Reference figures: ·
IG ON: 12.5 V ·
When cranking: 9.834 V ·
When idling (after warming up): 13.359 V |
| Battery Current Value (SOC) | Battery Current Value (SOC)
Min.: -2000 A, Max.: 4292967.2 A |
2 A: Idling | - |
| Battery Terminal Voltage | Battery Terminal Voltage
Min.: 0 V, Max.: 65.5 V |
- | - |
| Battery Status of Charge | Battery Status of Charge
Min.: 0%, Max.: 100% |
90%: Idling | - |
| Battery Monitor Module Calibration Status | Battery Monitor Module Calibration Status
Incmpl or Compl |
- | - |
| Target Alternator Electricity Generation Voltage | Target Alternator Electricity Generation Voltage
Min.: 0 V, Max.: 65.535 V |
- | - |
| Battery Control Mode (SOC) | Battery Control Mode (SOC)
14.3 V(Electric Load) / 14.3 V(Regeneration Brake) / 13.5 V(Manual AC) / 12.8 V(Initial Low) / 12.2 V to 14.3 V(SOC) / 12.2 V to 14.3 V(Current Feedback) |
- | - |
| Battery Current | Battery current:
Min.: -125 A, Max.: 125 A |
Changes in response to the amount of electricity generated by the alternator: while running after warming up. | When a malfunction occurs, there may be a problem with the IB voltage system or the sensor power source. |
| Battery Temperature | Battery temperature:
Min.: -40°C (-40°F), Max.: 6513.5°C (11756.3°F) |
Changes in response to the actual temperature: while running after warming up. | When a malfunction occurs, there may be a problem with the THB voltage system or the sensor power source. |
| Estimated Battery Temperature | Estimated Battery Temperature
Min.: -40°C (-40°F), Max.: 32727.5°C (58941.5°F) |
25°C (77°F): Idling | - |
| Alt Vol - Non Active Test | Displays the voltage required when the regulator is not being forcefully driven:
Min.: 0 V, Max.: 80 V |
Changes in response to the battery fluid temperature and running state (12.4 to 14.8 V): after starting the engine. | When a malfunction occurs, there may be problems with charging control systems. |
| Alt Vol - Active Test | Displays the voltage required when the regulator is being forcefully driven:
Min.: 0 V, Max.: 80 V |
Specified voltage required when performing the "generation required voltage" active test: after starting the engine. | ·
Displays the voltage generated when performing the active test. ·
When a malfunction occurs, there may be problems with the charging control systems. |
| Alternator Duty | Displays the charging control signal:
Min.: 0%, Max.: 255% |
69%: Idling | When a malfunction occurs, there may be problems with the charging control systems. |
| Request Voltage to Alternator | Displays the alternator generation control mode:
14.5 V / 12.8 V |
Changes in response to the amount of electricity generated by the alternator: while charging control. | When a malfunction occurs, there may be problems with the charging control systems.
Reference values:
·
14.5 V : Required alternator output voltage is High or Exhigh ·
12.8 V : Required alternator output voltage is Low |
| Alternator Mechanical Error Status | Alternator Mechanical Error Status
Normal or Abnormal |
- | - |
| Alternator Electrical Output Error Status | Alternator Electrical Output Error Status
Normal or Abnormal |
- | - |
| Alternator High Temperature Error Status | Alternator High Temperature Error Status
Normal or Abnormal |
- | - |
| Alternator Communication Error Status | Alternator Communication Error Status
Normal or Abnormal |
- | - |
| Regulator Temperature | Regulator Temperature
Min.: -40°C (-40°F), Max.: 980°C (1796°F) |
- | - |
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Active Test.
Perform the Active Test by referring to the table below.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Control the Voltage of Alternator | Fluctuations in the required alternator generated voltage. | Between 12.8 and 14.0 V | While engine running.
·
While engine running. ·
Test is possible when vehicle is stopped and engine is idling ·
Shift lever P or N position |