Home › Power Source / Network › FA20 (BATTERY / CHARGING) › CHARGING SYSTEM (for 150 A Type) › from 2019.03
RM2090E _57 Power Source / Network _060693 FA20 BATTERY / CHARGING _0396238 CHARGING SYSTEM(for 150 A Type) C

FA20 BATTERY / CHARGING  CHARGING SYSTEM(for 150 A Type)  P0A3B  Generator Over Temperature  


DESCRIPTION

The ECM outputs DTC P0A3B when the following conditions are met.

DTC No. DTC Detection Condition Trouble Area
P0A3B A generator assembly internal failure flag (high-temperature alert) is set and the internal temperature of the generator assembly is 168 °C (334 °F) or higher. Generator assembly

PROCEDURE

1.CHECK GENERATOR ASSEMBLY
a.

Turn the ignition switch off.


b.

Check for foreign material clogged in the generator assembly outlet.

OK:

There is not clogging.




OK

2.CHECK CHARGE WARNING LIGHT

NG

REMOVE ANY CLOGGED FOREIGN MATERIAL AND LEAVE THE ALTERNATOR AS IT IS FOR APPROXIMATELY 20 MINUTES TO COOL IT DOWN.

2.CHECK CHARGE WARNING LIGHT
a.

Turn the ignition switch off.


b.

Leave the alternator as it is for approximately 20 minutes.


c.

Check that the charge warning light comes on.

OK:

The charge warning light does not come on.




OK

NG

CHECK FOR FOREIGN MATERIAL CLOGGED IN THE ALTERNATOR OUTLET OR SURROUNDING AREA. TEMPORARY ALTERNATOR OVERHEAT OCCURRED, BUT IT IS RETURNED TO NORMAL NOW.