Home › Power Source / Network › FA20 (BATTERY / CHARGING) › GENERATOR (for 150 A Type) › from 2019.03
RM2090E _57 Power Source / Network _060693 FA20 BATTERY / CHARGING _0396239 GENERATOR(for 150 A Type) G

FA20 BATTERY / CHARGING  GENERATOR(for 150 A Type)  INSPECTION  


PROCEDURE

Hide 1.INSPECT BRUSH

a.
A277222C02
1.337,0.313 1.507,0.496 0.170,0.182 10 *a 0.855,0.471 1.024,0.653 0.170,0.182 10 *c 1.033,0.948 1.202,1.130 0.170,0.182 10 *b
*a Minimum length
*b Standard length
*c Mark of minimum length
V100145

Brush


Using a vernier caliper, measure the brush length.

Standard length:

22.5 mm (0.885 in)


Minimum length:

5.0 mm (0.196 in)


If the brush length is less than the minimum, replace the brush assembly.


b.
A391610

Using a dial tension gauge, check the brush spring force.

HINT:

Push in the brush spring and measure the brush spring force where the tip of the brush projects 2.0 mm (0.0787 in.) from the brush holder.


Standard brush spring force:

4.1 to 5.3 N (0.4 to 0.5 kgf, 0.9 to 1.2 lbf)


Minimum brush spring force:

1.7 N (0.2 kgf, 0.4 lbf)