Home › General › SPECIFICATIONS › FA20 BATTERY / CHARGING › from 2019.03
RM2090E _V1 General _060663 SPECIFICATIONS _0297446 FA20 BATTERY / CHARGING F

SPECIFICATIONS  FA20 BATTERY / CHARGING  TORQUE SPECIFICATIONS  


for 150 A Type
Part Tightened N*m kgf*cm ft.*lbf
IC regulator x Rotor and coil assembly Bolt A
2.0
20 18 in.*lbf
Bolt B
3.9
40 35 in.*lbf
Brush assembly x IC regulator 2.0 20 18 in.*lbf
Terminal B x Rear cover 8.9 91 79 in.*lbf
Generator assembly x V-ribbed belt tensioner assembly 25 255 18
Generator wire x Terminal 16 163 12
Battery negative terminal set bolt 6.0 61 53 in.*lbf

for 130 A Type
Part Tightened N*m kgf*cm ft.*lbf
Terminal x Generator rear end cover 8.9 91 79 in.*lbf
Generator regulator x Generator rear end cover Bolt A
2.0
20 18 in.*lbf
Bolt B
3.9
40 35 in.*lbf
Stator coil x Generator rear end cover 2.0 20 18 in.*lbf
Bearing retainer x Generator drive end frame 3.9 40 35 in.*lbf
Generator pulley x Generator rotor assembly 108 1101 80
Generator rear end cover x Generator drive end frame 4.4 45 39 in.*lbf
Generator assembly x V-ribbed belt tensioner assembly 25 255 18
Generator wire x Terminal 16 163 12
Battery negative terminal set bolt 6.0 61 53 in.*lbf