Home › Drivetrain › A4Q AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM › 2011.11–2015.08
RM19Y0E _52 Drivetrain _002983 A4Q AUTOMATIC TRANSMISSION / TRANSAXLE _0015077 AUTOMATIC TRANSMISSION SYSTEM C

A4Q AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P0773  Shift Solenoid "E" Electrical Malfunction  


DESCRIPTION

Shifting from 1st to 4th is performed in combination with ON and OFF operation of the shift solenoid valves SL1, SL2, SL3, SL, DSU and SR which is controlled by the TCM. If an open or short circuit occurs in any of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (Fail-safe function).

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate Memory
P0773 Shift Solenoid "E" Electrical Malfunction When electricity is applied to the shift solenoid valve SR, the condition that the current does not flow at all or overflow continues.
(1 trip detection logic)
·

Open or short in shift solenoid valve SR circuit

·

Shift solenoid valve SR

·

TCM


Come on Blinks DTC stored

·

MIL:"Comes on" means the MIL (Malfunction IndicatorLamp) illuminates.

·

Memory:"DTC stored" means the TCM stores the trouble code if the ECU detects the DTC detection condition.


WIRING DIAGRAM

C246495E03
0.792,2.542 2.604,3.302 1.813,0.76 10 ECT SOLENOID (SHIFT SOLENOID VALVE SR) 5.833,1.51 6.438,1.99 0.604,0.479 10 SOLR 0.813,2.375 1.302,2.729 0.49,0.354 10 E21 6.063,2.802 6.594,3.135 0.531,0.333 10 E10 6.052,2.958 6.604,3.271 0.552,0.313 10 TCM 2.375,1.427 2.792,1.792 0.417,0.365 10 H1 5.583,1.427 5.99,1.844 0.406,0.417 10 12 2.635,1.427 3.042,1.865 0.406,0.438 10 4

PROCEDURE

1.INSPECT SOLENOID WIRE (SR)
C130158C04
1.448,1.344 0.948,1.229 true 0.073,0.031 0.448,0.354 0.375,0.323 10 *a 0.49,1.125 1.438,1.604 0.948,0.479 10 4 (H1)
*a Rear view of wire harness connector
(to Solenoid wire)


a.

Disconnect the E21 solenoid wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
4 (H1) - Body ground 20°C (68°F) 14 to 18 Ω



c.

Reconnect the E21 solenoid wire connector.

Result:
proceed to
OK
NG




OK

2.CHECK HARNESS AND CONNECTOR (SOLENOID WIRE - TCM)

NG

3.INSPECT SHIFT SOLENOID VALVE SR
2.CHECK HARNESS AND CONNECTOR (SOLENOID WIRE - TCM)
a.

Disconnect the E10 TCM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
E10-12 (SOLR) - Body ground 20°C (68°F) 14 to 18 Ω



c.

Reconnect the E10 TCM connector.

Result:
proceed to
OK
NG




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SR
a.
C143834C02
0.104,0.073 0.49,0.438 0.385,0.365 10 *a 2.146,2.5 2.583,2.844 0.438,0.344 10 (+) 2.865,2.5 3.344,2.906 0.479,0.406 10 (-)
*a Component without harness connected
(Shift Solenoid Valve SR)


Remove the shift solenoid valve SR.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
Solenoid Connector (SR) - Solenoid Body (SR) 20°C (68°F) 14 to 18 Ω



c.

Connect the positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body.

OK:

The solenoid valve makes an operating sound.


Result:
proceed to
OK
NG




OK

NG