Home › Power Source / Network › K3-VE BATTERY / CHARGING › GENERATOR › 2011.11–2015.08
RM19Y0E _57 Power Source / Network _003002 K3-VE BATTERY / CHARGING _0015178 GENERATOR A

K3-VE BATTERY / CHARGING  GENERATOR  INSTALLATION  


PROCEDURE

Hide 27020 1.INSTALL GENERATOR ASSEMBLY

A285544N04
0.938,1.813 1.323,2.167 0.385,0.354 10 A 0.656,0.448 1.021,0.802 0.365,0.354 10 B 1.188,0.26 1.542,0.646 0.354,0.385 10 C

a.

Temporarily install the generator adjusting bar with bolt C.


b.

Temporarily install the generator with bolts A and B.


c.

Install the generator adjusting bar with bolt C.

Torque:
20 N*m (204 kgf*cm, 15 ft.*lbf)


d.

Connect the connector.


e.
A285622C04
0.49,0.479 0.979,0.865 0.49,0.385 10 *a
*a 45°


Position engine wire No. 2 as illustrated and install it with the nut.

Torque:
7.9 N*m (80 kgf*cm, 70 in.*lbf)


Hide 16361A 2.INSTALL FAN AND GENERATOR V BELT

Hide 16361A 3.ADJUST FAN AND GENERATOR V BELT

Hide 4.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Torque:
6.4 N*m (65 kgf*cm, 56 in.*lbf)