Home › Power Source / Network › POWER DISTRIBUTION › MAIN BODY ECU(for LHD) › from 2015.08
RM19Y0E _57 Power Source / Network _041460 POWER DISTRIBUTION _0192576 MAIN BODY ECU(for LHD) A

POWER DISTRIBUTION  MAIN BODY ECU(for LHD)  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:

Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.


NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION


Hide 55501A 3.REMOVE GLOVE COMPARTMENT DOOR SUB-ASSEMBLY

Hide 82673B 4.REMOVE JUNCTION BLOCK BRACKET

B417774

a.

Remove the 2 bolts and junction block bracket.


Hide 82600 5.REMOVE FUSE BLOCK ASSEMBLY

a.
B417775

Remove the bolt.


b.
B417776

Disconnect each connector and disengage the clamp.


c.
B414222

Pull down the lock lever to disconnect the connector.


d.
B417777

Disengage the 3 clamps.


e.