The battery temperature sensor installed on the battery current sensor assembly detects battery temperature.
A thermistor is integrated into the battery temperature sensor, and the resistance in the battery temperature sensor changes according to the battery temperature.
The resistance of the thermistor in the battery temperature sensor decreases as the battery temperature increases. The resistance increases as the temperature decreases.
The battery temperature sensor is connected to the ECM. The ECM supplies 5 V from the CM terminal to the battery temperature sensor through resistor R.
The battery temperature sensor and resistor R are connected in series. This results in fluctuations in the voltage supplied from the CM terminal when the resistance changes according to the battery temperature.
The ECM determines the battery temperature according to fluctuations in voltage. When the battery temperature is high, the ECM determines to reduce the amount of current supplied from the generator in order to protect the battery.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | Memory |
|---|---|---|---|---|---|
| P0515 | Battery Temperature Sensor System Malfunction | Battery temperature sensor output value is less than 0.2 V for 0.5 seconds or more with the engine switch to ON
Battery temperature sensor output value is more than 4.8 V for 0.5 seconds or more with the engine switch to ON (1 trip detection logic) |
·
Battery current sensor assembly (battery temperature sensor) ·
Short to GND in battery temperature sensor circuit ·
ECM |
Charging warning light does not come on | DTC stored |
Read freeze frame data using the GTS or Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored.
Disconnect the C50 ECM connector.
Disconnect the C42 battery current sensor assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C50-34 (BATP) - C42-1 (TEMP) | Always | Below 1Ω |
| C50-100 (E2) - C42-4 (GND) | Always | Below 1Ω |
| C50-34 (BATP) or C42-1 (TEMP) - Body ground and other terminals | Always | 10 kΩ or higher |
Reconnect the C50 ECM connector.
Reconnect the C42 battery current sensor assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the battery current sensor assembly with a new one.
Click herePower Source / Network>1NR-VE BATTERY / CHARGING>BATTERY CURRENT SENSOR>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Turn the ignition switch to ON.
Clear the DTCs.
Click herePower Source / Network>1NR-VE BATTERY / CHARGING>CHARGING SYSTEM>DTC CHECK / CLEAR
| Proceed to |
|---|
| NEXT |
NEXT
Check for DTCs.
Click herePower Source / Network>1NR-VE BATTERY / CHARGING>CHARGING SYSTEM>DTC CHECK / CLEAR
| Proceed to |
|---|
| DTC is output |
| DTC is not output |
DTC is output
DTC is not output