This DTC is stored when the +IG terminal voltage deviates from the DTC detection condition due to a malfunction in the power supply or charging circuit, such as the battery or generator circuit, etc.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Note |
|---|---|---|---|---|
| C1241/15 | Low or High Power Supply Voltage | 1.
Solenoid power supply voltage remains under the threshold value for a certain period of time. 2.
ECU indicates a power supply failure remains for a certain period of time. |
·
ABS2 fuse ·
ECU-IG1 fuse ·
Battery ·
Charging system ·
Power source circuit ·
Internal power supply circuit of skid control ECU (Brake actuator assembly) |
- |
| C1241/16 | Low or High Power Supply Voltage | When ECU power supply voltage goes over the threshold value. | ·
ABS2 fuse ·
ECU-IG1 fuse ·
Battery ·
Charging system ·
Power source circuit ·
Internal power supply circuit of skid control ECU (Brake actuator assembly) |
- |
Inspect the fuses for circuits related to this system before performing the following procedure.
If the skid control ECU (brake actuator assembly) is replaced with a new one, the skid control ECU makes the shift to test mode automatically when the ignition switch is turned to ON for the first time. Be sure to complete the test mode checks.
Check the battery voltage.
11 to 14 V
| Proceed to |
|---|
| OK |
| NG |
OK
NG
for 1NR-VE: Click herePower Source / Network>1NR-VE BATTERY / CHARGING>CHARGING SYSTEM>ON-VEHICLE INSPECTION
for 2NR-VE: Click herePower Source / Network>2NR-VE BATTERY / CHARGING>CHARGING SYSTEM>ON-VEHICLE INSPECTION
| *a | Front view of wire harness connector
(to Skid Control ECU (Brake Actuator Assembly)) |
Turn the ignition switch off.
Disconnect the A13 skid control ECU (brake actuator assembly) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A13-12 (+IG) - Body ground | Ignition switch ON | 11 to 14 V |
| A13-38 (+BS) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch off.
Disconnect the A13 skid control ECU (brake actuator assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A13-25 (GND1) - Body ground | Always | Below 1 Ω |
| A13-1 (GND2) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the ignition switch off.
Connect the GTS or Techstream to the DLC3.
Start the engine.
Turn the GTS or Techstream on.
Enter the following menus: Chassis / ABS/VSC/TRC / Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| +IG 1 voltage | +IG voltage value | Min.: 0.00 V
Max.: 20.00 V |
Ignition switch on: 11 to 14 V | Changes in proportion to battery voltage |
| Solenoid valve power voltage | +BS voltage value | Min.: 0.00 V
Max.: 20.00 V |
Always: 11.00 to 14.00 V | Changes in proportion to battery voltage |
Normal
Using the GTS or Techstream, check the input of the stop light switch operation when the brake pedal is operated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Clear the DTC.
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ANTI-LOCK BRAKE SYSTEM>DTC CHECK / CLEAR
Turn the ignition switch off.
Start the engine.
Drive the vehicle at a speed of 20 km/h (12 mph) or more.
Check if the same DTC is output.
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ANTI-LOCK BRAKE SYSTEM>PROBLEM SYMPTOMS TABLE
| Result | Proceed to |
|---|---|
| DTC not output | A |
| DTC output | B |
If troubleshooting has been carried out according to the problem symptoms table, refer back to the table and proceed to the next step.
Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ANTI-LOCK BRAKE SYSTEM>DTC CHECK / CLEAR
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B