MALFUNCTION DESCRIPTION
These DTCs are stored when the generator temperature sensor output is abnormal. The cause of this malfunction may be one of the following:
Internal generator temperature sensor malfunction
Open or short in generator temperature sensor
The connectors are not connected properly
Foreign matter or water on the connector terminals
Open or short in wire harness
If any of these DTCs are stored, the generator temperature sensor is malfunctioning and the self-protection function may not operate. Therefore under certain high load driving condition, the temperature of the generator (MG1) becomes high. If the self-protection function does not operate, the generator (MG1) may malfunction and cause the vehicle to enter fail-safe mode.
Refer to the description for DTC P0A3611.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A361C | Generator Temperature Sensor Voltage Out of Range | After a long soak, the value of the generator (MG1) temperature sensor is different from the value of the other temperature sensors.
(2 trip detection logic) |
·
Wire harness or connector ·
Hybrid vehicle transaxle assembly (Generator temperature sensor) |
Does not come on | Master Warning Light:
Comes on |
| P0A361F | Generator Temperature Sensor Circuit Intermittent | Sudden change in generator temperature sensor output or hunting:
Unusual sudden change in generator temperature sensor output occurs and offset condition continues for a certain period of time, or unusual change in motor temperature sensor output occurs repeatedly. (1 trip detection logic) |
·
Wire harness or connector ·
Hybrid vehicle transaxle assembly (Generator temperature sensor) |
Does not come on | Master Warning Light:
Comes on |
| DTC No. | Data List |
|---|---|
| P0A361C | ·
Generator Temperature ·
Motor Temperature ·
Inverter Coolant Temperature |
| P0A361F | Generator Temperature |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off.
Leave the vehicle as is for 5 hours or more and then check the values of the Data List items "Generator Temperature", "Motor Temperature" and "Inverter Coolant Temperature".
Turn the power switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
With power switch on (IG) and wait for 5 seconds or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for DTC P0A3611.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611
Connect the GTS to the DLC3.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Engine / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| No DTCs are output, or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| Relevant DTC | |
|---|---|
| P261029 | ECM/PCM Engine Off Timer Performance Signal Invalid |
Turn the power switch off.
A
B
Connect the GTS to the DLC3.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| No DTCs are output, or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| Relevant DTC | |
|---|---|
| P0A3611 | Generator Temperature Sensor Circuit Short to Ground |
| P0A3615 | Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open |
Turn the power switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Disconnect the hybrid vehicle control ECU connector.
| *a | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A49-26 (GMT) - A49-27 (GMTG) | Power switch off | 0.3338 to 1487 kΩ |
Reconnect the hybrid vehicle control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Disconnect the CA4 No. 1 engine room relay block connectors.
Disconnect the A49 hybrid vehicle control ECU connector.
Measure the resistance according to the value(s) in the table below.
When performing the measurement, lightly jiggle the wire harness up and down and left and right and confirm that the resistance does not fluctuate.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| CA4-15 (GMT) - A49-26 (GMT) | Power switch off | Below 1 Ω |
| CA4-16 (GMTG) - A49-27 (GMTG) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| CA4-15 (GMT) or A49-26 (GMT) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| CA4-16 (GMTG) or A49-27 (GMTG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Reconnect the A49 hybrid vehicle control ECU connector.
Reconnect the CA4 No. 1 engine room relay block connectors.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Disconnect the C9 generator temperature sensor connector.
Disconnect the CA4 No. 1 engine room relay block connectors.
Measure the resistance according to the value(s) in the table below.
When performing the measurement, lightly jiggle the wire harness up and down and left and right and confirm that the resistance does not fluctuate.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| CA4-15 (GMT) - C9-5 (GMT) | Power switch off | Below 1 Ω |
| CA4-16 (GMTG) - C9-4 (GMTG) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| CA4-15 (GMT) or C9-5 (GMT) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| CA4-16 (GMTG) or C9-4 (GMTG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Reconnect the CA4 No. 1 engine room relay block connectors.
Reconnect the C9 generator temperature sensor connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the CA4 No. 1 engine room relay block connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| CA4-15 (GMT) - CA4-16 (GMTG) | Power switch off | 0.3338 to 1487 kΩ |
Reconnect the CA4 No. 1 engine room relay block connectors.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A3611
| Proceed to |
|---|
| OK |
| NG |
OK
NG