Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › INVERTER WITH CONVERTER › 2016.10–2019.09
RM32K0E _51 Engine / Hybrid System _059620 HYBRID / BATTERY CONTROL _0292490 INVERTER WITH CONVERTER A

HYBRID / BATTERY CONTROL  INVERTER WITH CONVERTER  INSTALLATION  


PROCEDURE

Hide 1.INSTALL WIRE HARNESS CLAMP BRACKET

a.

Install the wire harness clamp bracket to the inverter with converter assembly with the bolt.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


b.

Install the wire harness clamp bracket to the inverter with converter assembly with the bolt.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


c.

Install the wire harness clamp bracket to the inverter with converter assembly with the bolt.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


Hide 33829E 2.INSTALL TRANSMISSION CONTROL CABLE BRACKET

a.

Install the transmission control cable bracket to the inverter with converter assembly with the bolt.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)


Hide G9215 3.INSTALL NO. 2 INVERTER BRACKET

a.
A391968C02
2.313,1.99 3.021,1.833 3.021,1.833 2.729,1.781 false 0.76,0.99 0.917,1.188 0.156,0.198 10 false 1 1.469,1.552 1.625,1.75 0.156,0.198 10 true 2 3.021,1.698 3.177,1.896 0.156,0.198 10 false *a
*a Wooden Block


Set the inverter with converter assembly on wooden blocks.

NOTICE:
A380508

Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.



b.

Temporarily install the No. 2 inverter bracket to the inverter with converter assembly with the 2 bolts.


c.

Fully tighten the 2 bolts in the order shown in the illustration.

Torque:
15 N*m (153 kgf*cm, 11 ft.*lbf)


Hide G9214 4.INSTALL NO. 1 INVERTER BRACKET

a.
A391967C02
2.24,2.021 2.896,1.854 2.896,1.854 2.604,1.813 false 2.927,1.74 3.24,1.938 0.313,0.198 10 false *a 0.635,1.021 0.844,1.229 0.208,0.208 10 false 1 1.583,1.521 1.76,1.708 0.177,0.188 10 true 2
*a Wooden Block


Temporarily install the No. 1 inverter bracket to the inverter with converter assembly with the 2 bolts.


b.

Fully tighten the 2 bolts in the order shown in the illustration.

Torque:
15 N*m (153 kgf*cm, 11 ft.*lbf)


Hide G9200 5.INSTALL INVERTER WITH CONVERTER ASSEMBLY

CAUTION:

Wear insulated gloves.


a.

Temporarily install the inverter with converter assembly with the 5 bolts and 2 nuts.

NOTICE:
·

When installing the inverter with converter assembly, be careful not to damage the parts around it.

·

To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

·
A391970C01
0.469,2.208 0.667,2.417 0.198,0.208 10 true *a 0.479,3.406 0.677,3.615 0.198,0.208 10 true *b
*a Correct
*b Incorrect


Make sure that the inverter with converter assembly is positioned so that the stud bolts are in contact with the base of the U-shaped portions of the No. 1 inverter bracket.



HINT:

If the bolts and nuts are not tightened appropriately, the inverter with converter assembly may make an abnormal noise.



b.

Fully tighten the bolt (A).

A391966N01
0.792,1.563 0.948,1.76 0.156,0.198 10 true A 2.469,1.354 2.625,1.552 0.156,0.198 10 true B 2.01,1.552 2.156,1.75 0.146,0.198 10 true B 1.479,1.458 1.625,1.635 0.146,0.177 10 true B 4.854,2.458 4.99,2.656 0.135,0.198 10 true D 5.198,2.458 5.323,2.656 0.125,0.198 10 true D 5.667,2.302 5.813,2.5 0.146,0.198 10 true C

Torque:
25 N*m (255 kgf*cm, 18 ft.*lbf)


c.

Fully tighten the 3 bolts (B).

Torque:
25 N*m (255 kgf*cm, 18 ft.*lbf)


d.

Fully tighten the bolt (C).

Torque:
25 N*m (255 kgf*cm, 18 ft.*lbf)


e.

Fully tighten the 2 nuts (D).

Torque:
25 N*m (255 kgf*cm, 18 ft.*lbf)


Hide G1148 6.CONNECT MOTOR CABLE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.

Temporarily connect the motor cable to the inverter with converter assembly with the 4 bolts.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.




b.
A376323C04
0.615,0.208 0.927,0.208 0.927,0.208 1.313,0.563 true 0.448,0.104 0.76,0.302 0.313,0.198 10 false *a 2.969,1.854 3.125,2.052 0.156,0.198 10 true A 0.448,1.969 0.625,2.156 0.177,0.188 10 true 2 0.792,2.656 0.979,2.854 0.188,0.198 10 true 1 2.646,2.458 2.813,2.646 0.167,0.188 10 true 3
*a Waterproof Seal


Fully tighten the bolt (A).

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


c.

Fully tighten the 3 bolts in the order shown in the illustration to connect the motor cable to the inverter with converter assembly.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


d.
A376322

Temporarily install the 6 bolts.

NOTICE:
·

To prevent the threads from being damaged, temporarily tighten the 6 bolts by hand.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.




e.

Using an insulated tool, fully tighten the 6 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Be sure to use a torque wrench to tighten the bolts.




Hide G9221 7.INSTALL INVERTER COVER

CAUTION:

Wear insulated gloves.


a.

Install the inverter cover to the inverter with converter assembly with the 2 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:
·

Visually confirm that the inverter cover waterproof seal is securely installed before installing the inverter cover.

·

Do not touch the waterproof seal of the inverter cover.

·

Make sure that the interlock is fully engaged.

·

Do not damage the terminals, interlock connector or inverter with converter assembly during installation.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·
A376320C03
2.167,2.115 2.656,1.635 2.656,1.635 2.031,1.24 false 1.031,0.313 1.302,0.313 1.302,0.313 1.823,0.781 true 0.865,0.188 1.177,0.385 0.313,0.198 10 false *a 2.698,1.521 3.01,1.719 0.313,0.198 10 false *1
*1 Inverter Cover
*a Screw


Do not remove or excessively tighten the screw of the inverter cover.

·

Although the inverter cover may feel loose, this is not due to a malfunction.

·
A376327C02
1.458,1.688 1.688,1.875 0.229,0.188 10 true *a
*a No Gap


Push in the inverter cover until it contacts the inverter with converter assembly.




Hide G922AA 8.CONNECT INLET NO. 1 INVERTER COOLING HOSE

a.
A376319C02
0.385,0.542 0.625,0.542 0.625,0.542 0.76,0.948 true 0.885,0.365 1.125,0.365 1.125,0.365 1.292,0.948 true 0.188,0.458 0.5,0.656 0.313,0.198 10 false *a 0.708,0.292 1.021,0.49 0.313,0.198 10 false *b 1.083,1.552 1.396,1.75 0.313,0.198 10 false *c 2.323,0.115 2.635,0.313 0.313,0.198 10 false *d 3.083,0.906 3.396,1.104 0.313,0.198 10 false *e 2.76,0.375 3.146,0.615 0.385,0.24 10 false 270°
*a Alignment Mark (Yellow)
*b Rib
*c 2 to 6 mm (0.0787 to 0.236 in.)
*d Up
*e LH Side


Connect the inlet No. 1 inverter cooling hose to the inverter with converter assembly and slide the clip to secure it.

NOTICE:

To prevent foreign matter from entering the inverter with converter assembly and inverter cooling system, do not remove the pieces of cloth from the pipe and disconnected hose until installation.


HINT:
·

Make sure that the clip is positioned as shown in the illustration.

·

Make sure to align the alignment mark of the hose with the rib of the inverter with converter assembly.




Hide G922C 9.CONNECT OUTLET NO. 1 INVERTER COOLING HOSE

a.
A376317C02
2.115,0.594 2.031,0.229 2.031,0.229 1.844,0.229 true 2.688,0.604 2.604,0.24 2.604,0.24 2.417,0.24 true 1.677,0.125 1.99,0.323 0.313,0.198 10 false *a 2.26,0.135 2.573,0.333 0.313,0.198 10 false *b 2.458,1.198 2.771,1.396 0.313,0.198 10 false *c
*a Alignment Mark (Yellow)
*b Rib
*c 2 to 6 mm (0.0787 to 0.236 in.)


Connect the outlet No. 1 inverter cooling hose to the inverter with converter assembly and slide the clip to secure it.

NOTICE:

To prevent foreign matter from entering the inverter with converter assembly and inverter cooling system, do not remove the pieces of cloth from the pipe and disconnected hose until installation.


HINT:
·

Make sure that the clip is positioned as shown in the illustration.

·

Make sure to align the alignment mark of the hose with the rib of the inverter with converter assembly.




Hide 82123 10.CONNECT NO. 3 ENGINE WIRE

CAUTION:

Wear insulated gloves.


a.
A376315

Engage the clamp and connect the No. 3 engine wire to the inverter with converter assembly.


b.

Temporarily install the nut.

NOTICE:

To prevent the threads from being damaged, temporarily tighten the nut by hand.



c.

Fully tighten the nut.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


d.

Engage the 2 claws to close the No. 3 engine wire terminal cover.


e.
A376313

Connect the No. 3 engine wire to the inverter with converter assembly with the bolt.

Torque:
8.5 N*m (87 kgf*cm, 75 in.*lbf)


f.
A376312

Connect the No. 3 engine wire to the inverter with converter assembly with the bolt.

Torque:
8.5 N*m (87 kgf*cm, 75 in.*lbf)


Hide 11.INSTALL WIRE HARNESS CLAMP BRACKET

a.

Install the wire harness clamp bracket to the inverter with converter assembly with the nut.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


Hide 821H2 12.CONNECT HV AIR CONDITIONING WIRE

CAUTION:

Wear insulated gloves.


a.

Engage the clamp.


b.
A375966

Connect the HV air conditioning wire to the inverter with converter assembly and install the 2 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connector.




Hide 821H1 13.CONNECT HV FLOOR UNDER WIRE

CAUTION:

Wear insulated gloves.


a.

Engage the 2 clamps.


b.
A375965

Connect the HV floor under wire to the inverter with converter assembly and install the 2 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connector.




Hide 82121 14.CONNECT ENGINE WIRE

CAUTION:

Wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.

Engage the clamp to connect the engine wire.


b.

Install the 2 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


c.

Install the inverter protector to the inverter with converter assembly with the bolt.

Torque:
9.5 N*m (97 kgf*cm, 84 in.*lbf)


d.

Engage the 2 clamps.


e.
A391971

Connect the 2 inverter with converter assembly connectors move the lock lever as shown in the illustration.

NOTICE:
·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

·

Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connectors.

·

Do not touch the waterproof seal or terminals of the connectors.




f.

Engage the 2 claws to connect the engine wire to the No. 1 engine room relay block.


g.

Connect the 3 No. 1 engine room relay block connectors.


h.

Install the No. 1 relay block cover to the No. 1 engine room relay block.


Hide 33820B 15.CONNECT TRANSMISSION CONTROL CABLE ASSEMBLY

a.

Engage the clamp to connect the transmission control cable assembly.


Hide 74404A 16.INSTALL BATTERY CLAMP SUB-ASSEMBLY

a.

Install the battery clamp sub-assembly to the vehicle with the 3 bolts.

Torque:
15.4 N*m (157 kgf*cm, 11 ft.*lbf)


Hide 19.INSTALL AUXILIARY BATTERY

Hide 82121 20.CONNECT ENGINE WIRE

a.

Connect the battery state sensor assembly connector.


b.

Engage the 2 claws to connect the engine wire to the battery current sensor holder.


Hide 21.ADD COOLANT (for Inverter)

Hide 51444A 23.INSTALL REAR ENGINE UNDER COVER LH