When the power switch is turned on (IG), auxiliary battery voltage is applied to the IGSW terminal of the ECM. The output signal from the MREL terminal of the ECM causes current to flow to the coil of the No. 1 integration relay (EFI-MAIN relay), closing the contacts of the EFI-MAIN relay and supplying power to terminals +B and +B2 of the ECM.
Inspect the fuses for circuits related to this system before performing the following procedure.
Disconnect the 1A No. 1 integration relay connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1A-10 - Body ground | Always | 11 to 14 V |
| 1B-3 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the No. 1 integration relay (EFI-MAIN relay, IG2 NO. 1 relay).
Click herePower Source / Network>POWER DISTRIBUTION>INTEGRATION RELAY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the No. 1 integration relay.
Disconnect the A38 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1A-9 - A38-6 (IGSW) | Always | Below 1 Ω |
| 1B-6 - A38-46 (MREL) | Always | Below 1 Ω |
| 1B-4 - A38-2 (+B) | Always | Below 1 Ω |
| 1B-4 - A38-3 (+B2) | Always | Below 1 Ω |
| 1A-9 or A38-6 (IGSW) - Body ground and other terminals | Always | 10 kΩ or higher |
| 1B-6 or A38-46 (MREL) - Body ground and other terminals | Always | 10 kΩ or higher |
| 1B-4 or A38-2 (+B) - Body ground and other terminals | Always | 10 kΩ or higher |
| 1B-4 or A38-3 (+B2) - Body ground and other terminals | Always | 10 kΩ or higher |
If a short is detected in any of the above circuits, there may be a malfunction in the circuit of a connected ECU.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the No. 1 integration relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1A-8 - Body ground | Always | Below 1 Ω |
| 1B-5 - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the C63 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C63-59 (E1) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to ECM) |
Disconnect the ECM connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-6 (IGSW) - Body ground | Power switch on (IG) | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F1 certification ECU (smart key ECU assembly) connector.
Disconnect the 1A No. 1 integration relay connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F1-17 (IG1D) - 1A-7 | Always | Below 1 Ω |
| F1-17 (IG1D) or 1A-7 - Body ground and other terminals | Always | 10 kΩ or higher |
If a short is detected in any of the above circuits, there may be a malfunction in the circuit of a connected ECU.
| Proceed to |
|---|
| OK |
| NG |
OK
NG