Home › Power Source / Network › 2ZR-FXE (BATTERY / CHARGING) › CHARGING SYSTEM
RM32K0E _57 Power Source / Network _060220 2ZR-FXE BATTERY / CHARGING _0295712 CHARGING SYSTEM G

2ZR-FXE BATTERY / CHARGING  CHARGING SYSTEM  ON-VEHICLE INSPECTION  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced when inspecting auxiliary battery are shown below.

Necessary Procedure After Parts Removed/Installed/Replaced
Replacement Part or Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link
Auxiliary battery terminal is disconnected/reconnected Memorize steering angle neutral point Lane departure alert system (w/ Steering Control) (Click here)
Simple intelligent parking assist system*1
Toyota parking assist-sensor system*1
Pre-collision system
Initialize back door lock Power door lock control system (Click here)

*1: When performing learning using the GTS.

Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>SIMPLE INTELLIGENT PARKING ASSIST SYSTEM>CALIBRATION

PROCEDURE

Hide 1.CHECK AUXILIARY BATTERY

a.

Check that the auxiliary battery cables are connected to the correct terminals.

If they are not, connect them properly.


b.

Check the auxiliary battery for damage and deformation. If severe damage, deformation or leakage is found, replace the auxiliary battery.


c.

Check the electrolyte level in each cell.

·

If the electrolyte level is below the lower line, replace the auxiliary battery.

·

If the electrolyte level is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte specific gravity.

Standard Specific Gravity:

1.25 or higher at 20°C (68°F)




Hide 2.CHECK AUXILIARY BATTERY VOLTAGE

a.

Turn the power switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.


b.

Measure the auxiliary battery voltage according to the value(s) in the table below.

Result:
Tester Connection Condition Specified Condition Result
Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Power switch off 12.0 V or higher Auxiliary battery is OK
12.0 V or less Recharge auxiliary battery



Hide 3.RECHARGE AUXILIARY BATTERY

a.

Recharge the auxiliary battery.

HINT:
·

Recharge the auxiliary battery according to the charger's instructions.

·

Apply the appropriate charging current according to the type of auxiliary battery shown in the table below.


Charge Method Charging Current
Normal Below 5 A
Quick Below 15 A



b.

Turn the power switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.


c.

Measure the auxiliary battery voltage according to the value(s) in the table below.

Result:
Tester Connection Condition Specified Condition Result
Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Power switch off 12.0 V or higher Auxiliary battery is OK
12.0 V or less Recharge auxiliary battery



Hide 4.CHECK AUXILIARY BATTERY TERMINAL, FUSIBLE LINK AND FUSE

a.
A392141C01
0.688,0.333 1.104,0.667 true 2.427,1.469 2.844,1.802 true 2.917,1.698 3.177,1.906 0.26,0.208 10 true *1 0.521,0.229 0.76,0.417 0.24,0.188 10 true *2
*1 Positive (+) Auxiliary Battery Terminal
*2 Negative (-) Auxiliary Battery Terminal


Check that the auxiliary battery terminals are not loose or corroded.

Torque:
Positive (+) Auxiliary Battery Terminal : 5.6 N*m (57 kgf*cm, 50 in.*lbf)
Negative (-) Auxiliary Battery Terminal : 5.4 N*m (55 kgf*cm, 48 in.*lbf)

If a terminal is loose or corroded, tighten or clean the terminal.


b.

Measure the resistance of each fusible link and fuse for the auxiliary battery charging system.

Standard Resistance:

Below 1 Ω


If the result is not as specified, replace the fusible link or fuse as necessary.


Hide 5.CHECK AMD TERMINAL

CAUTION:
·
A340386

This vehicle has contains high voltage circuits standardized with orange colored wiring and connectors, so follow the instructions in this manual to perform the procedures correctly.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

If the correct procedures are not followed according to the instructions in this manual, there is a danger of electric shock from the high voltage circuits.


·
A340358

Be sure to wear insulating gloves when working on high voltage wiring or components.

·

If work is performed without wearing insulating gloves, there is a danger of electric shock.




b.

Check that the AMD terminal is connected securely, and there is no contact problem.

If there are any arc marks, replace the affected parts.


c.
A392140C01
1.01,0.635 1.24,0.438 true 2.583,0.646 2.813,0.448 true 1.302,0.344 1.49,0.552 0.188,0.208 10 true *a 2.865,0.354 3.052,0.573 0.188,0.219 10 true *b
*a Inverter with Converter Assembly Side
*b No. 1 Engine Room Relay Block Side


Check that the nut for the AMD terminal is tightened to the specified torque.

Torque:
Inverter with Converter Assembly Side : 8.0 N*m (82 kgf*cm, 71 in.*lbf)
No. 1 Engine Room Relay Block Side : 8.0 N*m (82 kgf*cm, 71 in.*lbf)

If there are no arc marks and the AMD terminal connection is faulty, connect the AMD terminal securely.



Hide 6.CHECK DC/DC CONVERTER FUNCTION

a.
A111747C13
0.802,0.979 1.146,0.646 1.146,0.646 1.281,0.646 false 1.177,1.26 0.896,1.656 0.896,1.656 0.75,1.656 false 1.302,0.563 1.49,0.719 0.188,0.156 10 *a 0.552,1.563 0.75,1.708 0.198,0.146 10 *b
*a Probe Direction
*b Current Flowing into Auxiliary Battery


Connect the AC/DC 400 A probe to the positive (+) auxiliary battery cable.


b.

Turn the power switch on (READY) and leave the vehicle as is until the electric current flowing to the auxiliary battery becomes 10 A or less.


c.

Turn on the high beam headlights, and turn the blower motor switch to the HI position and the rear window defogger on.


d.
A314451C01
0.729,0.854 0.865,0.417 0.865,0.417 1.083,0.417 false 0.719,1.76 0.938,1.76 0.938,1.76 1.229,1.313 false 1.135,0.333 1.448,0.49 0.313,0.156 10 false *a 0.563,1.688 0.875,1.844 0.313,0.156 10 false *b
*a Probe Direction
*b Current Flowing from Auxiliary Battery


Measure the current and voltage according to the value(s) in the table below.

Result:
Item Tester Connection Condition Specified Condition
Current flowing from auxiliary battery Positive (+) auxiliary battery cable Power switch on (READY)
(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.)
0 A or less
(No current from auxiliary battery)
Auxiliary battery voltage Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 12.5 to 15 V


If the result is not as specified, replace the inverter with converter assembly.