The main body ECU (multiplex network body ECU) controls the front fog lights.
Inspect the fuses and bulbs for circuits related to this system before performing the following procedure.
Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.
Check the operation of the taillights.
Taillights operate normally.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Front Fog Light Relay | Front fog lights | ON/OFF | Light control switch in tail position |
| Tester Display |
|---|
| Front Fog Light Relay |
Front fog lights come on.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the FR FOG relay from the No. 4 relay block assembly.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Relay terminal 5 -Body ground | Power switch off | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 2 - Body ground | Light control switch TAIL or HEAD | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the FR FOG relay.
Click hereVehicle Exterior>LIGHTING (EXT)>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A36 fog light assembly LH connector.
Disconnect the A35 fog light assembly RH connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 3 - A36-2 (B) | Always | Below 1 Ω |
| Relay terminal 3 - A35-2 (B) | Always | Below 1 Ω |
| Relay terminal 3 or A36-2 (B) - Body ground | Always | 10 kΩ or higher |
| Relay terminal 3 or A35-2 (B) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 3A instrument panel junction block assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 1 - 3A-52 | Always | Below 1 Ω |
| Relay terminal 1 or 3A-52 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the instrument panel junction block assembly.
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3A-52 - MB-7 (FFGO) | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG (for LHD) | C |
| NG (for RHD) | D |
A
B
C
D
Disconnect the 3D instrument panel junction block assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 2 - 3D-11 | Always | Below 1 Ω |
| Relay terminal 2 or 3D-11 - Body ground | Always | 10 kΩ or higher |
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG | C |
A
B
C