The main body ECU (Multiplex Network Body ECU) receives a back door open/closed signal from back door lock assembly.
Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Back Door Courtesy SW | Back door courtesy switch signal | ON or OFF | ON: Back door open
OFF: Back door closed |
- |
| Tester Display |
|---|
| Back Door Courtesy SW |
Normal conditions listed above are displayed.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the back door lock assembly.
Click hereVehicle Interior>LIGHTING (INT)>BACK DOOR COURTESY SWITCH>REMOVAL
Inspect the back door courtesy switch built in the back door lock assembly.
Click hereVehicle Interior>LIGHTING (INT)>BACK DOOR COURTESY SWITCH>INSPECTION
Back door lock assembly is normal.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the 3H instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| S9-3(D+) - 3H-34 | Always | Below 1 Ω |
| S9-3(D+) or 3H-34 - Body ground | Always | 10 kΩ or higher |
| S9-2(ACT-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the instrument panel junction block assembly.
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(Instrument Panel Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3H-34 - MB-4 (BCTY) | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG (for LHD) | C |
| NG (for RHD) | D |
A
B
C
D