Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › MOTOR GENERATOR CONTROL COMPUTER › 2016.10–2019.09
RM32K0E _51 Engine / Hybrid System _059620 HYBRID / BATTERY CONTROL _0315584 MOTOR GENERATOR CONTROL COMPUTER A

HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL COMPUTER  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during motor generator control ECU kit removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedures Effect/Inoperative Function when Necessary Procedure not Performed Link

*1: When performing learning using the GTS.

Click here(Click here)

Disconnect cable from negative auxiliary battery terminal Memorize steering angle neutral point Lane departure alert system (w/ Steering Control) (Click here)
Simple intelligent parking assist system*1
Toyota parking assist-sensor system*1
Pre-collision system
Initialize back door lock Power door lock control system (Click here)
Replacement of inverter with converter assembly Resolver learning
·

DTCs are stored

·

Slight vibration at a vehicle speed of 5 km/h (3 mph) or less

·

Shock or vibration during acceleration


(Click here)
for SFI system

Replacement of ECM


Perform Vehicle Identification Number (VIN) registration MIL comes on (Click here)

CAUTION:
·
A340386

This vehicle has contains high voltage circuits standardized with orange colored wiring and connectors, so follow the instructions in this manual to perform the procedures correctly.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION

·

If the correct procedures are not followed according to the instructions in this manual, there is a danger of electric shock from the high voltage circuits.

·
A340358

Be sure to wear insulating gloves when working on high voltage wiring or components.

·

If work is performed without wearing insulating gloves, there is a danger of electric shock.



NOTICE:
A309734

·

If metal shavings are created when bolts are removed from the inverter with converter assembly, remove them using tape or equivalent.

·

Use non-residue type tape.



PROCEDURE

Hide G9200 1.REMOVE INVERTER WITH CONVERTER ASSEMBLY

Hide 33829E 2.REMOVE TRANSMISSION CONTROL CABLE BRACKET

Hide 4. VERIFY THAT VOLTAGE OF INVERTER WITH CONVERTER IS 0 V

CAUTION:

Wear insulating gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A393897C01
2.188,0.719 2.51,0.229 2.51,0.229 2.802,0.229 true 2.844,0.125 3.156,0.323 0.313,0.198 10 false *a
*a Tape


Remove the protective tape from the HV floor under wire opening.


b.
A393898C01
0.281,2.5 0.927,2.5 true 1.375,2.51 2.229,2.51 true 0.104,2.385 0.417,2.583 0.313,0.198 10 false *a 2.271,2.417 2.583,2.615 0.313,0.198 10 false *a
*a Voltage Measurement Position


Using a voltmeter, measure the voltage between the high voltage cable connector terminals.

Standard voltage:

0V


HINT:
·

Use measuring range of DC 750 V or more on the voltmeter.

·

If it is confirmed that high-voltage is not being applied to the inverter with converter assembly, the following procedures can be performed without using insulated tools or gloves.




c.

Apply protective tape to the area that was exposed.

NOTICE:

Use non-residue type tape.



Hide G9200 5.CLEAN INVERTER WITH CONVERTER ASSEMBLY

a.

Using a piece of cloth, clean the outside of the inverter with converter assembly and around the bolts.

NOTICE:

To prevent foreign matter from entering the inverter with converter assembly, make sure that the protective tape is not partially removed.



Hide 6. HOW TO PREVENT STATIC ELECTRICITY

SST
09890-47010  

NOTICE:
·

Static electricity should be eliminated when removing/installing the inverter with converter assembly.

·

Do not touch the electronic components of a circuit board.

·

Keep clothes away from electronic components.

·

Place the inverter with converter assembly and any removed electronic components on SST (antistatic mat).



a.
E104190N03
1.104,0.448 0.615,0.302 0.615,0.302 2.125,0.156 true 0.313,0.24 0.792,0.604 0.479,0.365 10 false SST

Wear an antistatic wrist strap.


b.

Connect the ground clip of the antistatic mat securely to a ground point provided in the workshop or on a workbench (anchor bolt).

HINT:

If the ground clip cable is too short, use an extension cable.



c.

Connect the ground clip of the antistatic wrist strap securely to the specified point of the antistatic mat.


d.

When handling internal components of the inverter with converter assembly, use only antistatic gloves or bare hands to prevent damage from static electricity or the entry of foreign matter.


Hide G9221 7.REMOVE INVERTER UPPER COVER

a.
A393711

Remove the 10 bolts.


b.

Using a screwdriver with its tip wrapped with protective tape, bend the 2 flanges of the inverter upper cover inward.

A393712C01
5.01,0.208 7.031,2.063 2.021,1.854 0.604,3.313 0.813,3.313 0.813,3.313 1.01,3.052 true 0.583,1.271 0.792,1.271 0.792,1.271 0.99,1.01 true 5.5,0.813 5.854,0.813 false 2.188,1.917 2.344,2.115 0.156,0.198 10 false A 2.948,1.729 3.073,1.896 0.125,0.167 10 true A 5.063,0.26 5.375,0.417 0.313,0.156 10 false *a 0.427,3.219 0.594,3.385 0.167,0.167 10 true *b 0.417,1.177 0.583,1.344 0.167,0.167 10 true *b 5.313,0.74 5.479,0.906 0.167,0.167 10 true *b
*a A-A Cross Section *b Protective Tape



c.

Using a screwdriver with its tip wrapped with protective tape, remove the inverter upper cover from the inverter with converter assembly in the order shown in the illustration.

A393713C01
0.344,1.083 0.448,1.417 0.448,1.417 0.625,1.417 false 2.302,4.052 2.406,4.385 2.406,4.385 2.583,4.385 true 6.333,1.25 6.208,1.49 6.208,1.49 6.021,1.49 true 6.51,3.906 6.385,4.146 6.385,4.146 6.198,4.146 true 0.573,4.313 0.969,4.313 true 0.656,1.323 0.844,1.5 0.188,0.177 10 true *a 3.073,1.76 3.229,1.948 0.156,0.188 10 true 1 1.688,1.823 1.844,2.01 0.156,0.188 10 false 2 4.094,0.615 4.25,0.781 0.156,0.167 10 false 3 5.031,1.417 5.188,1.583 0.156,0.167 10 false 4 0.375,4.219 0.563,4.396 0.188,0.177 10 true *a 5.833,1.396 6.021,1.573 0.188,0.177 10 true *a 6.021,4.073 6.208,4.25 0.188,0.177 10 true *a 2.615,4.292 2.802,4.469 0.188,0.177 10 true *a
*a Protective Tape - -


NOTICE:
·

Do not damage the sealing surfaces of the inverter with converter assembly.

·

Do not touch or allow grease or oil to contact the sealing surfaces of the inverter with converter assembly.

·

Be careful not to damage the sealing surfaces of the inverter with converter assembly.

·

To prevent internal components of the inverter with converter assembly from being damaged, do not insert the screwdriver excessively.




Hide 8.REMOVE SEAL PACKING FROM INVERTER WITH CONVERTER ASSEMBLY

NOTICE:
·

Do not allow any removed seal packing to enter the inverter with converter assembly.

·

Do not touch the circuit board.

·

Do not allow any moisture to come into contact.



a.

Using a finger, remove any seal packing that has seeped into the inverter with converter assembly.

HINT:

Make sure to remove any seal packing which has seeped toward the inside of inverter with converter assembly before installing the seal packing removal cover, otherwise the seal packing may be pushed into the inverter with converter assembly.



b.
A393714

Break off the seal packing removal cover and scraper at each break off line.


c.

Set the seal packing removal cover on the inverter with converter assembly and secure it by lightly pressing it at the 2 areas shown in the illustration.

A393715C01
0.135,0.667 1.677,2.302 1.542,1.635 4.958,0.438 7.01,2.458 2.052,2.021 0.177,0.708 0.49,0.865 0.313,0.156 10 false *a 5.01,0.49 5.323,0.646 0.313,0.156 10 false *b 2.583,0.479 2.781,0.646 0.198,0.167 10 true A 2.583,1.073 2.719,1.208 0.135,0.135 10 true A 3.615,1.583 3.74,1.75 0.125,0.167 10 true B 4.615,1.573 4.813,1.74 0.198,0.167 10 true B
*a A-A Cross Section *b B-B Cross Section
V100155

Push - -


NOTICE:

Make sure that the seal packing removal cover is in secure contact with the inside surface of the inverter with converter assembly without any gaps.



d.
A393716C01
1.896,0.802 2.146,0.427 2.146,0.427 2.49,0.427 true 2.542,0.323 2.854,0.521 0.313,0.198 10 false *a
*a MG Connector Opening


Place the inverter with converter assembly on its side on an antistatic mat as shown in the illustration.

NOTICE:
·

Make sure that the MG connector opening in the inverter with converter assembly is facing upward.

·

Make sure that the inverter with converter assembly is oriented correctly, otherwise seal packing may enter the inverter with converter assembly.




e.

Using a scraper, remove any remaining seal packing from the inverter with converter assembly.

NOTICE:
·

It is not necessary to remove small amounts of seal packing which are not easily scraped off.

A393901C02
2.24,0.958 2.479,0.76 2.479,0.76 2.844,0.76 true 4.5,0.938 4.74,0.74 4.74,0.74 5.146,0.74 true 4.375,1.365 4.615,1.167 4.615,1.167 4.979,1.167 true 1.865,0.083 2.094,0.24 0.229,0.156 10 false *a 4.167,0.083 4.396,0.24 0.229,0.156 10 false *b 2.115,1.542 2.344,1.698 0.229,0.156 10 false *c 4.448,1.563 4.677,1.719 0.229,0.156 10 false *c 2.906,0.688 3.219,0.885 0.313,0.198 10 false *d 5.198,0.656 5.51,0.854 0.313,0.198 10 false *e 5.021,1.083 5.333,1.281 0.313,0.198 10 false *f
*a Correct *b Incorrect
*c Width of Sealing Surface *d Difficult to Remove Seal Packing
*e Peeled Off Seal Packing *f Seal Packing Remaining on Full Width of Sealing Surface


·
A396292

Make sure to use the scraper supplied with the seal packing removal cover.



HINT:

Use the small end of the scraper to remove seal packing from small areas such as bolt holes.



f.

Using a clean piece of cloth, clean the sealing surfaces of the inverter with converter assembly.

NOTICE:
·

Do not use compressed air or a vacuum cleaner to clean the sealing surfaces of the inverter with converter assembly.

·

Do not use non-residue solvent to clean the sealing surfaces of the inverter with converter assembly.




g.
A393717

Remove the seal packing removal cover.

NOTICE:

Make sure that the inverter with converter assembly is oriented correctly, otherwise seal packing may enter the inverter with converter assembly when removing the seal packing removal cover.



h.

Check for and remove any foreign matter which has entered the inverter with converter assembly.


i.

Set the inverter with converter assembly upright.


j.

Clean the seal packing removal cover.

HINT:

As the seal packing removal cover will be reused, it is necessary to clean it to prevent foreign matter from entering the inverter with converter assembly and prevent damage.



Hide 04899 9.REMOVE MOTOR GENERATOR CONTROL ECU KIT

CAUTION:

To prevent foreign matter from entering the inverter with converter assembly, once the seal packing removal cover has been removed, work cannot be suspended until the motor generator control ECU kit is reinstalled.


NOTICE:
·

Do not touch the circuit board.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.



a.

Install the seal packing removal cover to the inverter with converter assembly.

HINT:

The seal packing removal cover is installed to help prevent the motor generator control computer kit from being damaged if a part or tool is dropped on it.



b.
A393718

Install the 2 guide pins by hand at the positions shown in the illustration.

NOTICE:

Make sure that the guide pins are tightened securely.



c.
A393719

Remove the seal packing removal cover.


d.
A393720C01
0,0 0,0 false
V100136

Unlock
V100144

Rib


Check that the 4 clips of the circuit board replacement jig are unlocked, and then while holding the circuit board replacement jig by the ribs, align it with the guide pins and set it on the inverter with converter assembly.

HINT:

Make sure that circuit board replacement jig is perfectly level with the sealing surface.



e.
A409833C04
2.625,3.021 2.948,3.021 true 2.042,2.156 2.354,2.354 0.313,0.198 10 false *a 2.979,2.958 3.292,3.156 0.313,0.198 10 false *b
*a Locked
*b Locked Position
V100135

Bolt
V100136

Lock


Secure the circuit board replacement jig with 2 inverter upper cover installation bolts.


f.

Lock the 4 clips as shown in the illustration to secure the circuit board replacement jig to the circuit board.

NOTICE:

When locking the clips of the circuit board replacement jig, do not apply excessive force to the clips, otherwise the circuit board replacement jig may be damaged.


HINT:

Make sure that the clips of the circuit board replacement jig are securely locked.



g.
A393722C01
0.354,2.292 0.5,2.292 0.5,2.292 0.781,2.469 true 1.427,3.823 1.667,3.677 1.667,3.677 1.792,3.677 true 0.135,2.896 0.448,3.052 0.313,0.156 10 false *a 0.292,4.094 0.604,4.25 0.313,0.156 10 false *b 0.073,2.229 0.427,2.396 0.354,0.167 10 false SST 1.854,3.615 2.167,3.771 0.313,0.156 10 false *c
*a Connected Vibration Dampening Connector
*b Disconnected Vibration Dampening Connector
*c Stopper of The Circuit Board Replacement Jig


Using SST, release the lock of each vibration dampening connector and raise the 20 vibration dampening connectors until they reach the stopper of the circuit board replacement jig.

SST
09905-00040  

NOTICE:

When disconnecting the vibration dampening connectors, release the lock of each connector with SST and then carefully lift the connector the specified amount.


HINT:
A393903C02
0.813,1.813 1.302,1.813 false 0.51,1.75 0.969,1.948 0.458,0.198 10 false SST

·

To prevent the vibration dampening connectors from being pulled up excessively, use both hands to raise them slowly as shown in the illustration.

·

The position of the lock will vary depending on the position of the vibration dampening connector. Refer to the arrows on the circuit board replacement jig.




h.
A393723C01
0,0 0,0 false
V100135

Bolt (A)
V100136

Bolt (B)


Remove the 3 bolts (A).

HINT:

If the bolts are difficult to remove from the circuit board replacement jig, use a magnet hand.



i.

Remove the 12 bolts (B).

HINT:

If the bolts are difficult to remove from the circuit board replacement jig, use a magnet hand.



j.

Remove the 2 inverter upper cover installation bolts.


k.
A393724C01
0,0 0,0 false
V100144

Rib


While holding the circuit board replacement jig by the ribs, evenly lift the circuit board replacement jig and circuit board straight up and remove it.


l.
A393740

Place the circuit board replacement jig upside down on a clean workbench.


m.

Check that the terminals of the inverter with converter assembly are not bent or damaged and that it is free of foreign matter.

A393902C01
2.906,0.604 3.292,0.604 false 6.292,0.625 6.677,0.625 false 1.844,0.063 2.115,0.229 0.271,0.167 10 false *a 5.135,0.094 5.406,0.26 0.271,0.167 10 false *b 3.333,0.521 3.604,0.688 0.271,0.167 10 false *c 6.729,0.542 7,0.708 0.271,0.167 10 false *c
*a Correct *b Incorrect
*c Terminal - -


NOTICE:
·

Do not touch the terminals.

·

If any of the terminals are bent, replace the inverter with converter assembly with a new one. Do not attempt to repair the terminals.




n.

Unlock the 4 circuit board replacement jig clips, and then while holding the sides of the circuit board or the top and bottom of the circuit board at the areas shown in the illustration, lift the circuit board to remove it from the circuit board replacement jig.

A393725C02
5.031,1.167 5.156,1.167 5.156,1.167 5.156,1.083 true 6.385,0.219 6.25,0.219 6.25,0.219 6.083,0.448 true 4.646,0.771 4.792,0.771 true 6.219,0.677 6.365,0.677 true 4.667,2.313 5,2.313 5,2.313 5.188,1.979 false 4.719,3.552 5.052,3.552 5.052,3.552 5.208,3.208 false 4.479,0.677 4.792,0.833 0.313,0.156 10 false *a 4.854,1.073 5.167,1.229 0.313,0.156 10 false *a 6.417,0.594 6.729,0.75 0.313,0.156 10 false *a 6.438,0.146 6.75,0.302 0.313,0.156 10 false *b 4.49,2.208 4.802,2.406 0.313,0.198 10 false *c 4.542,3.458 4.854,3.656 0.313,0.198 10 false *d
*a Hold here *b Do not hold here
*c Circuit Board *d Circuit Board Replacement Jig
V100135

Unlock - -


NOTICE:

Be careful not to touch any part of the circuit board other than the specified areas.