82641
1.INSTALL NO. 1 INTEGRATION RELAY
Connect the 2 connectors.
|
Install in this Direction |
Engage the claws to install the No. 1 integration relay as shown in the illustration.
82662A
2.INSTALL NO. 1 RELAY BLOCK COVER
|
Install in this Direction |
Engage the claws to install the No. 1 relay block cover as shown in the illustration.
3.CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL
for 2ZR-FXE:
Click hereGeneral>MAINTENANCE>2ZR-FXE AUXILIARY BATTERY>INSTALLATION
for M20A-FXS:
Click hereGeneral>MAINTENANCE>M20A-FXS AUXILIARY BATTERY>INSTALLATION
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION