Home › Engine / Hybrid System › 2ZR-FXE (HYBRID / BATTERY CONTROL) › MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY) › from 2019.09
RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404409 MOTOR GENERATOR CONTROL SYSTEM(for LITHIUM-ION BATTERY) C

2ZR-FXE HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM(for LITHIUM-ION BATTERY)  P0A6012  Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery  P0A6014  Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open  P0A601C  Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range  P0A601F  Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent  P0A6312  Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery  P0A6314  Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open  P0A631C  Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range  P0A631F  Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent  


DESCRIPTION

The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors its internal operation and will store DTCs if it detects a malfunction.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A6012 Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery Motor phase V current sensor high resolution signal circuit (short to +B)
(MIV)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning:
Comes on
P0A6014 Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open Motor phase V current sensor high resolution signal circuit (short to ground or open)
(MIV)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning:
Comes on
P0A601C Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range Motor phase V current sensor high resolution signal circuit (out of range)
(MIV)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning:
Comes on
P0A601F Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent Out of range detected in motor current sensor when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning:
Does not come on
P0A6312 Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery Motor phase W current sensor high resolution signal circuit (short to +B)
(MIW)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning:
Comes on
P0A6314 Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open Motor phase W current sensor high resolution signal circuit (short to ground or open)
(MIW)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning:
Comes on
P0A631C Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range Motor phase W current sensor high resolution signal circuit (out of range)
(MIW)
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning:
Comes on
P0A631F Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent Out of range detected in motor current sensor when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
·

Inverter with converter assembly

·

Wire harness or connector


Does not come on Master Warning:
Does not come on

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With power switch on (IG) and wait for 5 seconds or more.

7.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C56
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (MOTOR GENERATOR CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Motor Generator / Trouble Codes.


d.

Check for DTCs.

Powertrain > Motor Generator > Trouble Codes
50001 395
Result:
Result Proceed to
P0A6012, P0A6014, P0A601C, P0A601F, P0A6312, P0A6314, P0A631C or P0A631F only is output, or DTCs except the ones in the table below are also output. A
Any of the following DTCs including pending DTCs are also output. B


Malfunction Content Relevant DTC
Power source circuit malfunction P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
System malfunction P0A7873 Drive Motor "A" Inverter Actuator Stuck Closed

HINT:

P0A6012, P0A6014, P0A601C, P0A601F, P0A6312, P0A6314, P0A631C or P0A631F may be output as a result of the malfunctions indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





e.

Turn the power switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR