RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404409 MOTOR GENERATOR CONTROL SYSTEM(for LITHIUM-ION BATTERY) C

2ZR-FXE HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM(for LITHIUM-ION BATTERY)  P0C6413  Generator Position Sensor Circuit "A" Circuit Open  P0C641F  Generator Position Sensor Circuit "A" Circuit Intermittent  P0C6913  Generator Position Sensor Circuit "B" Circuit Open  P0C691F  Generator Position Sensor Circuit "B" Circuit Intermittent  


DTC SUMMARY

MALFUNCTION DESCRIPTION


These DTCs indicate that the resolver output signal is abnormal. The cause of this malfunction may be one of the following:


Area Main Malfunction Description
Inverter low-voltage circuit The connectors are not connected properly
Hybrid Vehicle Transaxle Assembly
·

Open circuit in the generator resolver circuit

·

Generator (MG1) internal malfunction (entry of foreign matter, etc.)


Wire harness between the resolver and inverter with converter assembly
·

Open circuit in the wire harness

·

The connectors are not connected properly


Inside of inverter Inverter with converter assembly internal circuit malfunction

DESCRIPTION

Refer to the system description for the Generator Resolver Circuit.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM (for LITHIUM-ION BATTERY)>Generator Resolver Circuit

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0C6413 Generator Position Sensor Circuit "A" Circuit Open Open in generator resolver sin phase circuit
(1 trip detection logic)
·

Inverter with converter assembly

·

Hybrid vehicle transaxle assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on
P0C641F Generator Position Sensor Circuit "A" Circuit Intermittent Open in generator resolver sin phase circuit detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
·

Inverter with converter assembly

·

Hybrid vehicle transaxle assembly

·

Wire harness or connector


Does not come on Master Warning:
Does not come on
P0C6913 Generator Position Sensor Circuit "B" Circuit Open Open in generator resolver cos phase circuit
(1 trip detection logic)
·

Inverter with converter assembly

·

Hybrid vehicle transaxle assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on
P0C691F Generator Position Sensor Circuit "B" Circuit Intermittent Open in generator resolver cos phase circuit detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored.
(1 trip detection logic)
·

Inverter with converter assembly

·

Hybrid vehicle transaxle assembly

·

Wire harness or connector


Does not come on Master Warning:
Does not come on

HINT:

If either of these DTCs is output, an open in the sin or cos phase circuit is suspected.


CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With power switch on (IG) and wait for 5 seconds or more.

7.

Turn the power switch on (READY) and wait for 5 seconds or more.

8.

Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.

9.

Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more.

10.

Drive the vehicle backward with the shift lever in R for 5 m (16 ft.) or more.

11.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

12.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




WIRING DIAGRAM

CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C56
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


HINT:
·

If the problem symptom cannot be reproduced, performing a road test on a road on which the vehicle tends to vibrate will make it easier to reproduce the symptom.

·

If the resolver is malfunctioning, the vehicle may not drive smoothly.

·

When inspecting the connectors, if it is difficult to judge if a connector was disconnected, deformed or improperly secured, disconnect and reconnect the connector and then check for DTCs again. Check if the same DTC is output. If the same DTC is not output, improper connection of connectors is suspected.

·

As a malfunction detection threshold may be exceeded when performing the vibration or heat connector inspections, make sure to perform the following inspection to check that the DTC was not stored due to the malfunction of a part.



PROCEDURE

1.CHECK DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Result:
Result Proceed to
P0C6413, P0C641F, P0C6913 or P0C691F only is output, or DTCs except the ones in the table below are also output. A
DTCs of hybrid control system in the tables below are output. B
DTCs of motor generator control system in the tables below are output. C


Table 1
Malfunction Content System Relevant DTC
Insulation Malfunction Hybrid control system P1C7C49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
P1C7D49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
P1C7E49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
P1C7F49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure

Table 2
Malfunction Content System Relevant DTC
Microcomputer malfunction Motor generator control system P0A1A47 Generator Control Module Watchdog / Safety MC Failure
P0A1A49 Generator Control Module Internal Electronic Failure
P1C2A1C Generator A/D Converter Circuit Circuit Voltage Out of Range
P1C2A49 Generator A/D Converter Circuit Internal Electronic Failure
P1C2B1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
P1C2B49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
P313483 Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect
P313486 Communication Error from Drive Motor "A" to Generator Signal Invalid
P313487 Communication Error from Drive Motor "A" to Generator Missing Message
Hybrid control system P0A1B49 Drive Motor "A" Control Module Internal Electronic Failure
Power source circuit malfunction Motor generator control system P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
Communication malfunction Motor generator control system P312487 Lost Communication between Drive Motor "A" and HV ECU Missing Message

HINT:

P0C6413, P0C641F, P0C6913 or P0C691F may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





e.

Turn the power switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

C

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

3.CHECK GENERATOR RESOLVER CIRCUIT

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK GENERATOR RESOLVER CIRCUIT

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM (for LITHIUM-ION BATTERY)>Generator Resolver Circuit

HINT:

If the "Generator Resolver Circuit" inspection results are normal, perform the next step.


Result:
Proceed to
NEXT



NEXT