Home › Engine / Hybrid System › 2ZR-FXE (HYBRID / BATTERY CONTROL) › HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY) › from 2019.09
RM32K0E _51 Engine / Hybrid System _083958 2ZR-FXE HYBRID / BATTERY CONTROL _0404410 HYBRID BATTERY SYSTEM(for LITHIUM-ION BATTERY) C

2ZR-FXE HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM(for LITHIUM-ION BATTERY)  P30004B  Hybrid/EV Battery Control System Over Temperature  


DESCRIPTION

The battery ECU assembly monitors the temperature of the HV battery to detect if it becomes excessively high.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P30004B Hybrid/EV Battery Control System Over Temperature The battery ECU assembly detects a HV battery cooling system error signal.
(1 trip detection logic)
·

Hybrid vehicle control ECU

·

No. 1 HV supply stack sub-assembly

·

No. 2 HV supply stack sub-assembly


Does not come on Master Warning:
Comes on

HINT:

The normal HV battery temperature is 60°C (140°F) or less.


Related Data List
DTC No. Data List
P30004B
·

Hybrid Battery Temperature 1 to 6

·

Hybrid Battery Cooling Fan Intake Air Temperature 1

·

Ambient Temperature

·

WOUT Control Limit Power

·

WIN Control Limit Power

·

Hybrid Battery SOC

·

Hybrid Battery Cooling Fan 1 Frequency



CONFIRMATION DRIVING PATTERN

HINT:

After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Drive the vehicle for approximately 10 minutes according to the freeze frame data items "Vehicle Speed", "Hybrid Battery Temperature 1 to 6", "Hybrid Battery Cooling Fan Intake Air Temperature 1", "Ambient Temperature" and "Hybrid Battery Current".

7.

Enter the following menus: Powertrain / HV Battery / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C02
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.

If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.

·
A358021C06
0.604,4.135 0.917,4.333 0.313,0.198 10 false *a 2.719,4.135 3.031,4.333 0.313,0.198 10 false *b
*a Dealer
*b Battery Collection Agent


When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

-

Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.


·

Before returning the HV battery, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HV BATTERY (for LITHIUM-ION BATTERY)>RECOVERY INSPECTION

·

Before returning the HV supply stack sub-assembly, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>HV BATTERY (for LITHIUM-ION BATTERY)>RECOVERY INSPECTION

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery and HV supply stack sub-assemblies.

·
A358020

After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (HV BATTERY, HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / HV Battery and Hybrid Control / Trouble Codes.


d.

Check for DTCs.

Powertrain > HV Battery > Trouble Codes
50001 398
Result:
Result Proceed to
"P30004B" only is output, or DTCs except the ones in the table below are also output. A
DTCs of hybrid battery system in the table below are output. B
DTCs of hybrid control system in the table below are output. C


System Relevant DTC
Hybrid battery system P060A47 Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure
P060B49 Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure
P060687 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message
P0A8111 Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground
P0A8115 Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open
P0A8196 Hybrid/EV Battery Cooling Fan 1 Component Internal Failure
P0A9B11 Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Ground
P0A9B15 Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open
P0A9B1C Hybrid/EV Battery Temperature Sensor "A" Voltage Out of Range
P0A9B2A Hybrid/EV Battery Temperature Sensor "A" Signal Stuck In Range
P0AAC11 Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground
P0AAC15 Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open
P0AC511 Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Ground
P0AC515 Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open
P0AC51C Hybrid/EV Battery Temperature Sensor "B" Voltage Out of Range
P0AC52A Hybrid/EV Battery Temperature Sensor "B" Signal Stuck In Range
P0ACA11 Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Ground
P0ACA15 Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open
P0ACA1C Hybrid/EV Battery Temperature Sensor "C" Voltage Out of Range
P0ACA2A Hybrid/EV Battery Temperature Sensor "C" Signal Stuck In Range
P0AE811 Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Ground
P0AE815 Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Auxiliary Battery or Open
P0AE81C Hybrid/EV Battery Temperature Sensor "D" Voltage Out of Range
P0AE82A Hybrid/EV Battery Temperature Sensor "D" Signal Stuck In Range
P0BC211 Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Ground
P0BC215 Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Auxiliary Battery or Open
P0BC21C Hybrid/EV Battery Temperature Sensor "E" Voltage Out of Range
P0BC22A Hybrid/EV Battery Temperature Sensor "E" Signal Stuck In Range
P0C3311 Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Ground
P0C3315 Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Auxiliary Battery or Open
P0C331C Hybrid/EV Battery Temperature Sensor "F" Voltage Out of Range
P0C332A Hybrid/EV Battery Temperature Sensor "F" Signal Stuck In Range
P306562 Hybrid/EV Battery Temperature Sensor "Group 1" Signal Compare Failure
P306A62 Hybrid/EV Battery Temperature Sensor "Group 2" Signal Compare Failure
Hybrid control system P0A1F94 Hybrid/EV Battery Energy Control Module Unexpected Operation


e.

Turn the power switch off.



A

2.REPLACE HYBRID VEHICLE CONTROL ECU

B

C

2.REPLACE HYBRID VEHICLE CONTROL ECU

NEXT