The cause of the malfunction may be the cooling system.
Check whether the grille is blocked, whether coolant is leaking, the HV radiator fan operating condition and whether coolant has frozen.
| Area | Inspection |
|---|---|
| Grille blockage, coolant amount, coolant hoses, HV radiator fan | Check for overheating due to hybrid cooling system malfunction. |
| Inverter coolant temperature sensor (built-in inverter) | Check for temperature sensor malfunction. |
| Coolant freezing check | Check freeze frame values to determine whether the hybrid coolant was frozen when the DTC was stored. |
| Data List |
|---|
·
Inverter Coolant Water Temperature ·
Motor Inverter Temperature ·
Generator Inverter Calculated Temperature ·
Boosting Converter Temperature (Upper) ·
Boosting Converter Temperature (Lower) ·
Ambient Temperature ·
Inverter Water Pump Revolution |
The inverter converts the high-voltage direct current of the HV battery into alternating current for the generator (MG1) and motor (MG2). The inverter generates heat during the conversion process. Therefore, the inverter is cooled by a special cooling system consisting of the inverter water pump assembly, the cooling fan, and a radiator. This cooling system is independent of the engine cooling system. The hybrid vehicle control ECU monitors the inverter water pump assembly, cooling fan and cooling system, and detects malfunctions.
| *1 | Inverter Water Pump Assembly | *2 | Inverter Reserve Tank Assembly |
| *3 | Inverter with Converter Assembly | *4 | Radiator Assembly (HV) |
| *5 | Hybrid Vehicle Transaxle Assembly | - | - |
This diagnostic procedure is referenced to in the diagnostic procedure of several DTCs.
If the result of this diagnostic procedure is normal, proceed as directed in the procedure for the DTC.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Make sure that the front side of the radiator grille is not blocked with anything.
Ask the customer if the front side of the radiator grille was blocked with anything.
| Result | Proceed to |
|---|---|
| Not blocked | A |
| Is/was blocked | B |
If the radiator grille is blocked, the inverter coolant temperature will increase and this DTC may be stored.
A
B
Check the HV coolant level in the inverter reserve tank.
Check for HV coolant leaks.
| Result | Proceed to |
|---|---|
| No leaks are found and the HV coolant level in the inverter reserve tank assembly is above the low line | A |
| No leaks are found and the HV coolant level in the inverter reserve tank assembly is below the low line | B |
| HV coolant leaks are evident | C |
After repairing the HV coolant leaks and adding coolant, perform the Active Tests "Activate the Inverter Water Pump" (Hybrid Control System) and "Control the Engine Cooling Fan" (Engine Control system) and make sure that there are no malfunctions.
If there are signs of coolant leakage around the connecting parts of a hose and the inverter with converter assembly, replace the hose with a new one.
A
B
C
Check that the cooling system hoses are not kinked or clogged.
The cooling system hoses are not kinked or clogged.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Engine / Active Test / Control the Engine Cooling Fan.
| Tester Display |
|---|
| Control the Engine Cooling Fan |
Perform the "Control the Engine Cooling Fan" Active Test.
| Result | Proceed to |
|---|---|
| Cooling fan operate | A |
| Cooling fan does not operate | B |
| Cooling fan do not stop |
Turn the power switch off.
A
B
Make sure that the HV coolant level is above the low line of the inverter reserve tank.
Be sure to perform the inspection with the auxiliary battery voltage at 12 V or more.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Inverter Water Pump.
Select the Data List item "Inverter Water Pump Revolution".
| Active Test Display |
|---|
| Activate the Inverter Water Pump |
| Data List Display |
|---|
| Inverter Water Pump Revolution |
According to the display on the GTS, perform the Active Test "Activate the Inverter Water Pump" and check the value of the Data List item "Inverter Water Pump Revolution".
| Tester Display | Condition | Specified Condition |
|---|---|---|
| Inverter Water Pump Revolution | Power switch on (IG)
During Active Test |
3176 to 8617 rpm |
Perform the Active Test with the inverter coolant temperature between -15 and 65°C (5 to 149°F).
When the inverter water pump assembly is not operating, the Data List item "Inverter Water Pump Revolution" displays a value 200 rpm or less.
Turn the power switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the power switch on (READY) and wait for 1 minute with the engine stopped.
Enter the following menus: Powertrain / Hybrid Control / Data List / Generator Inverter Calculated Temperature, Motor Inverter Temperature, Boosting Converter Temperature (Upper), Boosting Converter Temperature (Lower) and, Inverter Coolant Water Temperature.
| Tester Display |
|---|
| Generator Inverter Calculated Temperature |
| Motor Inverter Temperature |
| Boosting Converter Temperature (Upper) |
| Boosting Converter Temperature (Lower) |
| Inverter Coolant Water Temperature |
Read the Data List with the engine stopped.
| Result | Proceed to |
|---|---|
| Other than below | A |
| "Inverter Coolant Water Temperature" value is higher than the displayed temperature of any other Data List item by 20°C (68°F) or more | B |
The lower limit temperature that can be displayed for "Generator Inverter Calculated Temperature", "Motor Inverter Temperature", "Boosting Converter Temperature (Upper)" and "Boosting Converter Temperature (Lower)" is 15°C (59°F). The lower limit temperature for "Inverter Coolant Water Temperature" is -40°C (-40°F). The "Inverter Coolant Water Temperature" value displayed on the GTS may be lower than the others, but this is not a malfunction.
Turn the power switch off.
A
B
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>INVERTER WITH CONVERTER>REMOVAL
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read the freeze frame data item Ambient Temperature using the GTS.
Check if the freeze frame data item Ambient Temperature is below the freezing temperature of the HV coolant.
| Result | Proceed to |
|---|---|
| Ambient Temperature value is above freezing temperature of the HV coolant | A |
| Ambient Temperature value is below freezing temperature of the HV coolant | B |
HV coolant (SLLC) with a 30% concentration freezes at -15°C (5°F) and HV coolant (SLLC) with a 50% concentration freezes at -35°C (-31°F).
If the HV coolant freezes in the HV radiator or inverter water pump, the coolant temperature in the inverter with converter assembly rises because the HV coolant cannot circulate. As a result, a DTC may be stored.
A DTC is stored when the inverter water pump impeller cannot rotate due to freezing of the HV coolant.
If DTCs are output due to freezing of the LLC, the problem symptom cannot be reproduced. Check the LLC replacement history and whether the LLC was frozen based on the ambient temperature when the DTCs were stored.
Turn the power switch off.
A
B
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the connector connections and contact pressure of the relevant terminals for the inverter water pump assembly connector.
The connector is connected securely, the terminals are not deformed or corroded and there are no contact problems.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the hybrid vehicle control ECU connector.
Disconnect the inverter water pump assembly connector.
| *a | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| *b | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A97-34 (IWP) - A6-3 (SWP) | Power switch off | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A97-34 (IWP) or A6-3 (SWP) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
Reconnect the inverter water pump assembly connector.
Reconnect the hybrid vehicle control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to perform the inspection with the auxiliary battery voltage at 12 V or more.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the GTS to the DLC3.
| *1 | No. 1 Engine Room Relay Block |
| *2 | INV W/PMP Fuse |
Remove the INV W/PMP fuse from No. 1 engine room relay block.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Data List / Inverter Water Pump Revolution.
| Tester Display |
|---|
| Inverter Water Pump Revolution |
Read the Data List.
| Tester Display | Condition | Specified Condition |
|---|---|---|
| Inverter Water Pump Revolution | Power switch on (IG) | 200 rpm or less |
Turn the power switch off.
Install the INV W/PMP fuse.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID VEHICLE CONTROL ECU>REMOVAL
Disconnect the hybrid vehicle control ECU connector.
Remove the INV W/PMP relay from the No. 1 engine room relay block.
| *1 | No. 1 Engine Room Relay Block |
| *a | INV W/PMP Relay Holder |
Connect terminals 3 and 5 of the INV W/PMP relay holder.
Make a short circuit between terminals 3 and 5 to supply +B voltage to the inverter water pump.
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
*b | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A97-34 (IWP) - F161-3 (E1) | INV W/PMP relay holder terminals 3 and 5 connected
Power switch off |
11 to 14 V |
Make sure to check for and clear DTCs after performing this inspection.
Install the INV W/PMP relay.
Reconnect the hybrid vehicle control ECU connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the table below.
Turn the power switch on (IG).
While turning the power switch on (IG), check the waveform between the hybrid vehicle control ECU terminals.
| *a | Component with harness connected
(Hybrid Vehicle Control ECU) |
- | - |
| Item | Content |
|---|---|
| Terminal | A97-34 (IWP) - F161-3 (E1) |
| Equipment Setting | 5 V/DIV., 50 ms./DIV. |
| Condition | Power switch on (IG) |
Waveform duty ratio is between 3% and 9%.
Turn the power switch off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID VEHICLE CONTROL ECU>REMOVAL
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>WATER PUMP WITH MOTOR>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
After replacing the inverter water pump assembly, add HV coolant and perform air bleeding.
Click hereGeneral>MAINTENANCE>M20A-FXS COOLANT (for Inverter)>REPLACEMENT
| Proceed to |
|---|
| NEXT |
NEXT