Home › Engine / Hybrid System › M20A-FXS (HYBRID / BATTERY CONTROL) › INVERTER WITH CONVERTER › 2019.09–2020.08
RM32K0E _51 Engine / Hybrid System _083959 M20A-FXS HYBRID / BATTERY CONTROL _0404415 INVERTER WITH CONVERTER A

M20A-FXS HYBRID / BATTERY CONTROL  INVERTER WITH CONVERTER  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during inverter with converter assembly removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedures Effect/Inoperative Function when Necessary Procedure not Performed Link

*1: When performing learning using the GTS.

Click here(Click here)

Disconnect cable from negative auxiliary battery terminal Perform steering sensor zero point calibration Lane departure alert system (w/ Steering Control) (Click here)
Toyota parking assist-sensor system*1
Parking support brake system*1
Simple intelligent parking assist system*1
Pre-collision system
Memorize steering angle neutral point Panoramic view monitor system (Click here)
Initialize back door lock Power door lock control system (Click here)
Replacement of inverter with converter assembly Resolver learning
·

DTCs are stored

·

Slight vibration at a vehicle speed of 5 km/h (3 mph) or less

·

Shock or vibration during acceleration


(Click here)
for M20A-FXS

Replacement of ECM


Perform Vehicle Identification Number (VIN) registration MIL comes on (Click here)

CAUTION:
·
A340386

Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.

Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM>PARTS LOCATION

·
A340358

Be sure to wear insulating gloves when working on high voltage wiring or components.

·

If work is performed without wearing insulating gloves, there is a danger of electric shock.



PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 51444A 3.REMOVE REAR ENGINE UNDER COVER LH

Hide 4.DRAIN COOLANT (for Inverter)

Hide 6.REMOVE AIR CLEANER CAP WITH AIR CLEANER HOSE

Hide 17801 7.REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

Hide 17701 8.REMOVE AIR CLEANER CASE SUB-ASSEMBLY

a.
A443735

Remove the 3 bolts and remove the air cleaner case sub-assembly.


Hide 33820B 9.SEPARATE TRANSMISSION CONTROL CABLE ASSEMBLY

a.
A434959

Remove the bolt.


b.

Disengage the 2 clamps to separate the transmission control cable assembly.


Hide 82121 10.DISCONNECT ENGINE WIRE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A443737

Move the lock lever as shown in the illustration and disconnect the inverter with converter assembly connector.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Insulate the disconnected terminals with insulating tape.




Hide 11.REMOVE CONNECTOR COVER ASSEMBLY

CAUTION:

Be sure to wear insulated gloves.


a.
A443739C01
2.094,1.083 2.344,1.281 0.25,0.198 10 true *a 1.792,0.396 2.042,0.594 0.25,0.198 10 true *b
*a Bolt (A)
*b Bolt (B)


Remove the bolt (B).


b.

Using a T25 "TORX" socket wrench, remove the bolt (A) and connector cover assembly from the inverter with converter assembly.

NOTICE:
·

Do not touch the connector cover assembly waterproof seal.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.




Hide 12.CHECK TERMINAL VOLTAGE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A443740

Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.

Standard Voltage:

0 V


HINT:

Use a measuring range of DC 750 V or more on the voltmeter.



Hide 13.TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY

CAUTION:

Be sure to wear insulated gloves.


a.
A443741

Temporarily install the connector cover assembly to the inverter with converter assembly.


b.

Using a T25 "TORX" socket wrench, install the bolt.

Torque:
4.5 N*m (46 kgf*cm, 40 in.*lbf)

NOTICE:

Do not touch the waterproof seal of the connector cover assembly.



Hide 821H1 14.DISCONNECT HV FLOOR UNDER WIRE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A443742C01
0.844,0.573 1.188,0.573 true 1.188,0.458 1.5,0.656 0.313,0.198 10 false *a
*a Waterproof Seal


Remove the bolt and disconnect the HV floor under wire from the inverter with converter assembly.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Insulate the disconnected terminals with insulating tape.




b.

Disengage the 2 clamps.


Hide 821H2 15.DISCONNECT HV AIR CONDITIONING WIRE

CAUTION:

Be sure to wear insulated gloves.


a.
A443743C01
1.177,0.594 1.625,0.594 true 1.635,0.49 1.948,0.688 0.313,0.198 10 false *a
*a Waterproof Seal


Remove the 2 bolts and disconnect the HV air conditioning wire from the inverter with converter assembly.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Insulate the disconnected terminals with insulating tape.




b.

Disengage the clamp.


Hide 16.REMOVE WIRE HARNESS CLAMP BRACKET

CAUTION:

Be sure to wear insulated gloves.


a.
A443744

Remove the nut and wire harness clamp bracket.


Hide 82121 17.DISCONNECT ENGINE WIRE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A443745

Move the lock lever as shown in the illustration and disconnect the inverter with converter assembly connector.

NOTICE:
·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Insulate the disconnected terminals with insulating tape.

·

Do not touch the waterproof seal or terminals of the connector.




b.
A443746

Remove the No. 1 relay block cover from the No. 1 engine room relay block.


c.
A443747

Disconnect the 3 No. 1 engine room relay block connectors.


d.

Disengage the 2 claws to separate the engine wire from the No. 1 engine room relay block.


e.
A443748

Remove the bolt and disconnect the engine wire from the inverter with converter assembly.


f.
A443749

Remove the bolt and disconnect the engine wire from the inverter with converter assembly.


g.
A443750

Disengage the 2 claws and open the engine wire terminal cover.


h.
A443751

Remove the nut.


i.

Disengage the 2 clamps and disconnect the engine wire from the inverter with converter assembly.


j.

Remove the 2 nuts.

A443752


k.

Disengage the clamp and disconnect the engine wire.


Hide G922C 18.DISCONNECT OUTLET NO. 1 INVERTER COOLING HOSE

a.
A443753

Slide the clip and disconnect the outlet No. 1 inverter cooling hose assembly from the inverter with converter assembly.

NOTICE:

Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.



Hide G922AA 19.DISCONNECT INLET NO. 1 INVERTER COOLING HOSE

a.
A443754

Slide the clip and disconnect the inlet No. 1 inverter cooling hose from the inverter with converter assembly.

NOTICE:

Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.



Hide 17771A 20.REMOVE AIR CLEANER BRACKET

a.
A443755

Disengage the clamp.


b.

Remove the bolt and air cleaner bracket.


Hide G9221 21.REMOVE INVERTER COVER

CAUTION:

Be sure to wear insulated gloves.


a.
A443756C01
1.479,2.615 1.76,2.052 1.76,2.052 1.375,2.406 true 1.5,2.781 1.625,3.031 1.625,3.031 1.865,3.031 true 2.948,2.573 2.906,3.104 2.906,3.104 2.677,3.104 false 0.625,2.677 0.677,2.125 0.677,2.125 0.885,2.125 false 1.885,2.948 2.198,3.146 0.313,0.198 10 false *a 1.781,1.958 2.094,2.156 0.313,0.198 10 false *b 2.552,3.021 2.708,3.219 0.156,0.198 10 false A 0.927,2.042 1.083,2.24 0.156,0.198 10 false A
*a Interlock
*b Waterproof Seal


Remove the 2 bolts and inverter cover from the inverter with converter assembly.

NOTICE:
·

Make sure to pull the inverter cover straight out, as a connector is connected to the inside of the inverter cover.

·

Do not touch the waterproof seal of the inverter cover.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

When removing the inverter cover, do not pull the areas (A) as they may deform.

·

Make sure that the interlock is installed to the inverter cover.

·
A376320C02
2.167,2.115 2.656,1.635 2.656,1.635 2.031,1.24 false 1.031,0.313 1.302,0.313 1.302,0.313 1.823,0.781 true 0.865,0.208 1.177,0.406 0.313,0.198 10 false *a 2.698,1.542 3.01,1.74 0.313,0.198 10 false *1
*1 Inverter Cover
*a Screw


Do not remove or excessively tighten the screw of the inverter cover.

·

Although the inverter cover may feel loose, this is not due to a malfunction.



HINT:
A443757C01
1.177,1.656 0.99,1.656 0.99,1.656 0.844,1.448 true 1.146,1.563 1.385,1.76 0.24,0.198 10 true *a
*a Protective Tape


If necessary, use a screwdriver with its tip wrapped with protective tape as shown in the illustration to remove the inverter cover.



Hide G1148 22.DISCONNECT MOTOR CABLE

CAUTION:

Be sure to wear insulated gloves.


a.
A443758

Using an insulated tool, remove the 6 bolts.

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.




b.
A443759C01
0.969,0.208 1.281,0.208 1.281,0.208 1.667,0.531 true 0.802,0.104 1.115,0.302 0.313,0.198 10 false *a
*a Waterproof Seal


Remove the 4 bolts and disconnect the motor cable from the inverter with converter assembly.

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Insulate the disconnected terminals with insulating tape.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·
A443760

To prevent the wire harness from being caught, make sure to bundle the wire harness using insulating tape or equivalent.




Hide G9200 23.REMOVE INVERTER WITH CONVERTER ASSEMBLY

CAUTION:

Be sure to wear insulated gloves.


a.

Remove the 5 bolts, 2 nuts and inverter with converter assembly.

A443761

NOTICE:
·

When removing the inverter with converter assembly, be careful not to damage the parts around it.

·

To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.



HINT:

Even after the coolant is drained, coolant remains in the inverter due to its internal structure. Therefore, seal or cover the pipes when removing the inverter with converter assembly so that coolant does not spill out.



Hide G9214 24.REMOVE NO. 1 INVERTER BRACKET

NOTICE:
A443762C01
0.875,1.094 1.75,1.958 1.75,1.958 2.396,1.135 true 0.135,0.125 0.448,0.281 0.313,0.156 10 false *a 1.698,1.99 2.01,2.146 0.313,0.156 10 false *b
*a Bottom of Inverter with Converter Assembly
*b Support


Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.


a.
A443763C01
2.125,2 2.948,2 2.948,2 2.563,1.813 false 2.958,1.885 3.271,2.083 0.313,0.198 10 false *a
*a Wooden Block


Set the inverter with converter assembly on wooden blocks.


b.

Remove the 2 bolts and No. 1 inverter bracket from the inverter with converter assembly.


Hide G9215 25.REMOVE NO. 2 INVERTER BRACKET

a.
A443764C01
2.26,1.969 3.031,1.813 3.031,1.813 2.677,1.74 false 3.052,1.708 3.302,1.938 0.25,0.229 10 false *a
*a Wooden Block


Remove the 2 bolts and No. 2 inverter bracket from the inverter with converter assembly.


Hide 33829E 26.REMOVE TRANSMISSION CONTROL CABLE SUPPORT

a.
A443765

Remove the bolt and transmission control cable support from the inverter with converter assembly.


Hide 27.REMOVE WIRE HARNESS CLAMP BRACKET

a.
A443766

Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.


b.
A443767

Remove the bolt and wire harness clamp bracket from the inverter with converter assembly.


c.
A443768

Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.


Hide G921E 28.REMOVE INVERTER PROTECTOR

a.
A443769

Remove the bolt and inverter protector from the inverter with converter assembly.