The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during service plug grip removal/installation are shown below.
This vehicle has contains high voltage circuits standardized with orange colored wiring and connectors, so follow the instructions in this manual to perform the procedures correctly.
for NICKEL METAL HYDRIDE BATTERY:
for LITHIUM-ION BATTERY:
If the correct procedures are not followed according to the instructions in this manual, there is a danger of electric shock from the high voltage circuits.
Be sure to wear insulating gloves when working on high voltage wiring or components.
If work is performed without wearing insulating gloves, there is a danger of electric shock.
When the cable is disconnected / reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is driven
Learning completes when vehicle is operated normally
1. PRECAUTION
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
2.CHECK FOR DTC
Check for DTCs.
for NICKEL METAL HYDRIDE BATTERY:
for LITHIUM-ION BATTERY:
Confirm that DTC P0AA649 (Hybrid / EV Battery Voltage System Isolation Internal Electronic Failure), P1C7C49 (Hybrid / EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure), P1C7D49 (Hybrid / EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure), P1C7E49 (Hybrid / EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure) or P1C7F49 (Hybrid / EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure) is not output before removing or installing the HV battery assembly. If this DTC is output, perform troubleshooting for this DTC first.
To reduce the risk of electric shock, do not perform troubleshooting before checking for DTCs.
3.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
58441E
4.REMOVE BATTERY SERVICE HOLE COVER
G3834
5.REMOVE SERVICE PLUG GRIP
Wear insulated gloves.
Do not inspect or service the high voltage system with the service plug grip installed.
To reduce the risk of electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
To reduce the risk of electric shock, make sure to wait at least 10 minutes after removing the service plug grip to fully discharge the high voltage capacitor inside the inverter with converter assembly.
Keep the removed service plug grip in your pocket to prevent other technicians from accidentally installing it while you are servicing the vehicle.
After removing the service plug grip, turning the power switch on (READY) may cause a malfunction. Do not turn the power switch on (READY) unless instructed by the repair manual.
Do not touch the terminals of the service plug grip.
If the service plug grip has been struck or dropped, replace it.
Waiting for at least 10 minutes is required to discharge the high voltage capacitor inside the inverter with converter assembly.
While wearing insulated gloves, rotate the handle of the service plug grip and remove the service plug grip as indicated by the arrows, in the order shown in the illustration.