The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during inverter with converter assembly removal/installation are shown below.
Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.
Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>HYBRID CONTROL SYSTEM>PARTS LOCATION
Be sure to wear insulating gloves when working on high voltage wiring or components.
If work is performed without wearing insulating gloves, there is a danger of electric shock.
When the cable is disconnected / reconnected to the battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is driven
Learning completes when vehicle is operated normally
1. PRECAUTION
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
G3834
2.REMOVE SERVICE PLUG GRIP
51444A
3.REMOVE REAR ENGINE UNDER COVER LH
4.DRAIN COOLANT (for Inverter)
89661
5.REMOVE ECM
6.REMOVE AIR CLEANER CAP WITH AIR CLEANER HOSE
17801
7.REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
17701
8.REMOVE AIR CLEANER CASE SUB-ASSEMBLY
Remove the 3 bolts and remove the air cleaner case sub-assembly.
33820B
9.SEPARATE TRANSMISSION CONTROL CABLE ASSEMBLY
Remove the bolt.
Disengage the 2 clamps to separate the transmission control cable assembly.
82121
10.DISCONNECT ENGINE WIRE
Be sure to wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Move the lock lever as shown in the illustration and disconnect the inverter with converter assembly connector.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Insulate the disconnected terminals with insulating tape.
11.REMOVE CONNECTOR COVER ASSEMBLY
Be sure to wear insulated gloves.
| *a | Bolt (A) |
| *b | Bolt (B) |
Remove the bolt (B).
Using a T25 "TORX" socket wrench, remove the bolt (A) and connector cover assembly from the inverter with converter assembly.
Do not touch the connector cover assembly waterproof seal.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
12.CHECK TERMINAL VOLTAGE
Be sure to wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.
0 V
Use a measuring range of DC 750 V or more on the voltmeter.
13.TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY
Be sure to wear insulated gloves.
Temporarily install the connector cover assembly to the inverter with converter assembly.
Using a T25 "TORX" socket wrench, install the bolt.
Do not touch the waterproof seal of the connector cover assembly.
821H1
14.DISCONNECT HV FLOOR UNDER WIRE
Be sure to wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
| *a | Waterproof Seal |
Remove the bolt and disconnect the HV floor under wire from the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Insulate the disconnected terminals with insulating tape.
Disengage the 2 clamps.
821H2
15.DISCONNECT HV AIR CONDITIONING WIRE
Be sure to wear insulated gloves.
| *a | Waterproof Seal |
Remove the 2 bolts and disconnect the HV air conditioning wire from the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Insulate the disconnected terminals with insulating tape.
Disengage the clamp.
16.REMOVE WIRE HARNESS CLAMP BRACKET
Be sure to wear insulated gloves.
Remove the nut and wire harness clamp bracket.
82121
17.DISCONNECT ENGINE WIRE
Be sure to wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Move the lock lever as shown in the illustration and disconnect the inverter with converter assembly connector.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
Insulate the disconnected terminals with insulating tape.
Do not touch the waterproof seal or terminals of the connector.
Remove the No. 1 relay block cover from the No. 1 engine room relay block.
Disconnect the 3 No. 1 engine room relay block connectors.
Disengage the 2 claws to separate the engine wire from the No. 1 engine room relay block.
Remove the bolt and disconnect the engine wire from the inverter with converter assembly.
Remove the bolt and disconnect the engine wire from the inverter with converter assembly.
Disengage the 2 claws and open the engine wire terminal cover.
Remove the nut.
Disengage the 2 clamps and disconnect the engine wire from the inverter with converter assembly.
Remove the 2 nuts.
Disengage the clamp and disconnect the engine wire.
G922C
18.DISCONNECT OUTLET NO. 1 INVERTER COOLING HOSE
Slide the clip and disconnect the outlet No. 1 inverter cooling hose assembly from the inverter with converter assembly.
Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.
G922AA
19.DISCONNECT INLET NO. 1 INVERTER COOLING HOSE
Slide the clip and disconnect the inlet No. 1 inverter cooling hose from the inverter with converter assembly.
Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.
17771A
20.REMOVE AIR CLEANER BRACKET
Disengage the clamp.
Remove the bolt and air cleaner bracket.
G9221
21.REMOVE INVERTER COVER
Be sure to wear insulated gloves.
| *a | Interlock |
| *b | Waterproof Seal |
Remove the 2 bolts and inverter cover from the inverter with converter assembly.
Make sure to pull the inverter cover straight out, as a connector is connected to the inside of the inverter cover.
Do not touch the waterproof seal of the inverter cover.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
When removing the inverter cover, do not pull the areas (A) as they may deform.
Make sure that the interlock is installed to the inverter cover.
| *1 | Inverter Cover |
| *a | Screw |
Do not remove or excessively tighten the screw of the inverter cover.
Although the inverter cover may feel loose, this is not due to a malfunction.
| *a | Protective Tape |
If necessary, use a screwdriver with its tip wrapped with protective tape as shown in the illustration to remove the inverter cover.
G1148
22.DISCONNECT MOTOR CABLE
Be sure to wear insulated gloves.
Using an insulated tool, remove the 6 bolts.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the connector.
| *a | Waterproof Seal |
Remove the 4 bolts and disconnect the motor cable from the inverter with converter assembly.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Insulate the disconnected terminals with insulating tape.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
To prevent the wire harness from being caught, make sure to bundle the wire harness using insulating tape or equivalent.
G9200
23.REMOVE INVERTER WITH CONVERTER ASSEMBLY
Be sure to wear insulated gloves.
Remove the 5 bolts, 2 nuts and inverter with converter assembly.
When removing the inverter with converter assembly, be careful not to damage the parts around it.
To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.
To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
Even after the coolant is drained, coolant remains in the inverter due to its internal structure. Therefore, seal or cover the pipes when removing the inverter with converter assembly so that coolant does not spill out.
G9214
24.REMOVE NO. 1 INVERTER BRACKET
| *a | Bottom of Inverter with Converter Assembly |
| *b | Support |
Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.
| *a | Wooden Block |
Set the inverter with converter assembly on wooden blocks.
Remove the 2 bolts and No. 1 inverter bracket from the inverter with converter assembly.
G9215
25.REMOVE NO. 2 INVERTER BRACKET
| *a | Wooden Block |
Remove the 2 bolts and No. 2 inverter bracket from the inverter with converter assembly.
33829E
26.REMOVE TRANSMISSION CONTROL CABLE SUPPORT
Remove the bolt and transmission control cable support from the inverter with converter assembly.
27.REMOVE WIRE HARNESS CLAMP BRACKET
Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.
Remove the bolt and wire harness clamp bracket from the inverter with converter assembly.
Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.
G921E
28.REMOVE INVERTER PROTECTOR
Remove the bolt and inverter protector from the inverter with converter assembly.