| Detection Item | Symptom | Trouble Area |
|---|---|---|
| Motor Generator Control ECU Communication Stop Mode | Any of the following conditions are met:
·
·
|
·
Inverter with converter assembly branch line or connector ·
Power source circuit of inverter with converter assembly ·
Inverter with converter assembly ground circuit ·
Inverter with converter assembly |
for LHD
for RHD
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
for M20A-FXS: Click hereEngine / Hybrid System>M20A-FXS (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
for 2ZR-FXE with NICKEL METAL HYDRIDE BATTERY: Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>PRECAUTION
for 2ZR-FXE with LITHIUM-ION BATTERY: Click hereEngine / Hybrid System>2ZR-FXE (HYBRID / BATTERY CONTROL)>MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY)>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
Inspect the fuses for circuits related to this system before performing the following procedure.
Before measuring the resistance of the CAN bus, turn the power switch off and leave the vehicle for 1 minute or more without operating the key or any switches, or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.
After the power switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Some parts must be initialized and set when replacing or removing and installing parts.
Click hereGeneral>SETUP>WHEN REPLACING OR REMOVING/INSTALLING PARTS>WORK PROCEDURE
After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.
DTC check procedure: Turn the power switch on (IG) and wait for 1 minute or more.
Then operate the suspected malfunctioning system and drive the vehicle at 60 km/h (37 mph) or more for 5 minutes or more.
After the repair, perform the CAN bus check and check that all the ECUs and sensors connected to the CAN communication system are displayed as normal.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM
Before disconnecting related connectors for inspection, push in on each connector body to check that the connector is not loose or disconnected.
When a connector is disconnected, check that the terminals and connector body are not cracked, deformed or corroded.
Check the vehicle specification.
| Result | Proceed to |
|---|---|
| for 2ZR-FXE | A |
| for M20A-FXS | B |
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the inverter with converter assembly connector.
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C65-1 (CANH) - C65-7 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C65-23 (GND2) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | Below 1 Ω |
| C65-24 (GND1) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | Below 1 Ω |
Reconnect the cable to the negative (-) auxiliary battery terminal.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C65-5 (+B2) - Body ground | Power switch on (IG) | 11 to 14 V |
| C65-6 (+B) - Body ground | Power switch on (IG) | 11 to 14 V |
| C65-12 (IGCT) - Body ground | Power switch on (IG) | 11 to 14 V |
| Result |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the inverter with converter assembly connector.
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C98-1 (CANH) - C98-7 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 54 to 69 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C98-23 (GND2) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | Below 1 Ω |
| C98-24 (GND1) - Body ground | Cable disconnected from negative (-) auxiliary battery terminal | Below 1 Ω |
Reconnect the cable to the negative (-) auxiliary battery terminal.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C98-5 (+B2) - Body ground | Power switch on (IG) | 11 to 14 V |
| C98-6 (+B) - Body ground | Power switch on (IG) | 11 to 14 V |
| C98-12 (IGCT) - Body ground | Power switch on (IG) | 11 to 14 V |
| Result |
|---|
| OK |
| NG |
OK
NG