Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System with Top-mounted Air Conditioner Pressure Sensor)
RM32H0E _58 Vehicle Interior _059841 HEATING / AIR CONDITIONING _0298707 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System with Top-mounted Air Conditioner Pressure Sensor) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System with Top-mounted Air Conditioner Pressure Sensor)  B1411  Room Temperature Sensor Circuit  


DESCRIPTION

The cooler (room temp. sensor) thermistor is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the cooler (room temp. sensor) thermistor changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the cooler (room temp. sensor) thermistor and reads voltage changes due to changes in the resistance of the cooler (room temp. sensor) thermistor.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1411 Room Temperature Sensor Circuit Any of the following conditions is met:
·

Open in cooler thermistor (room temperature sensor) circuit

·

Short in cooler thermistor (room temperature sensor) circuit


·

Cooler (room temp. sensor) thermistor

·

Harness or connector between cooler (room temp. sensor) thermistor and air conditioning amplifier assembly

·

Air conditioning amplifier assembly


Memorized
(4 seconds or more)*

*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.


HINT:

If the cabin temperature is approximately -56.0°C (-68.8°F) or lower, DTC B1411 may be output even though the system is normal.


DTC Detection Conditions
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition Ignition switch ON ○ ○
Malfunction Status Open in cooler thermistor (room temperature sensor) circuit ○ -
Short in cooler thermistor (room temperature sensor) circuit - ○
Detection Time 4 seconds or more 4 seconds or more
Number of Trips 1 trip 1 trip

HINT:

DTC will be output when conditions for either of the patterns in the table above are met.


WIRING DIAGRAM

E357698E01
0.125,1.75 0.583,1.948 0.458,0.198 10 false F60 0.125,1.906 2.677,2.146 2.552,0.24 10 false Cooler (Room Temp. Sensor) Thermistor 2.125,0.656 2.344,0.854 0.219,0.198 10 false 1 2.146,1.156 2.365,1.354 0.219,0.198 10 false 2 4.542,0.667 4.76,0.865 0.219,0.198 10 false 30 4.802,0.677 5.021,0.875 0.219,0.198 10 false TR 4.542,1.167 4.76,1.365 0.219,0.198 10 false 31 4.802,1.167 5.198,1.385 0.396,0.219 10 false SG-1 5.667,0.271 5.969,0.458 0.302,0.188 10 false 5 V 6.26,0.781 6.552,0.948 0.292,0.167 10 false AD 4.667,1.781 5.125,1.979 0.458,0.198 10 false F72 4.656,1.927 6.938,2.167 2.281,0.24 10 false Air Conditioning Amplifier Assembly

PROCEDURE

1.READ VALUE USING GTS (ROOM TEMPERATURE SENSOR)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Cooler (room temp. sensor) thermistor Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed -
Body Electrical > Air Conditioner > Data List
Tester Display
Room Temperature Sensor
50003 121 1
OK:

The display is as specified in the normal condition column.



Result:
Result Proceed to
NG A
OK (When troubleshooting according to Problem Symptoms Table) B
OK (When troubleshooting according to the DTC) C



A

2.INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR

B

C

4.CHECK FOR DTC
2.INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR
a.

Remove the cooler (room temp. sensor) thermistor.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR>REMOVAL


b.

Inspect the cooler (room temp. sensor) thermistor.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR>INSPECTION


Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)

NG

REPLACE COOLER (ROOM TEMP. SENSOR) THERMISTOR

3.CHECK HARNESS AND CONNECTOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the F72 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F72-30 (TR) - F60-1 Always Below 1 Ω
F72-31 (SG-1) - F60-2 Always Below 1 Ω
F72-30 (TR) or F60-1 - Body ground Always 10 kΩ or higher
F72-31 (SG-1) or F60-2 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK FOR DTC


Result:
Result Proceed to
DTCs are not output A
DTCs are output B



A

B

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY