The ion generator sub-assembly operates when both the ion generator switch and the blower switch are on. The air conditioning amplifier assembly sends a drive signal to the ion generator sub-assembly. When the ion generator sub-assembly receives the drive signal and starts to operate, it outputs an operation condition signal to the air conditioning amplifier assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B14B9 | Open in Ion Generator Circuit | Open in ion generator sub-assembly circuit | ·
Harness or connector between ion generator sub-assembly and power source circuit ·
Harness or connector between ion generator sub-assembly and body ground ·
Harness or connector between ion generator sub-assembly and air conditioning amplifier assembly ·
Ion generator sub-assembly ·
Air conditioning amplifier assembly |
Memorized
(12 seconds or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
Inspect the fuses for circuits related to this system before performing the following procedure.
Connect the GTS to the DLC3.
Turn the ignition switch ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Ion Generator | Ion generator sub-assembly | OFF or ON | - |
| Tester Display |
|---|
| Ion Generator |
Ion generator sub-assembly operates normally.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC) | C |
A
B
C
Disconnect the G2 ion generator sub-assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G2-1 (IG+) -Body ground | Ignition switch ON | 11 to 14 V |
| G2-1 (IG+) -Body ground | Ignition switch off | Below 1 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G2-4 (GND) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F72 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F72-17 (NAIN) - G2-3 (IG+) | Always | Below 1 Ω |
| F72-37 (NANO) - G2-2 (PCL) | Always | Below 1 Ω |
| F72-17 (NAIN) or G2-3 (IG+) - Body ground | Always | 10 kΩ or higher |
| F72-37 (NANO) or G2-2 (PCL) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the F72 air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G2-3 (IG+) - Body ground | ·
Ignition Switch ON ·
Blower switch off |
3.5 to 5 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the G2 air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
- | - |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| F72-17 (NAIN) - Body ground | ·
Ignition Switch ON ·
Blower switch Lo |
Below 2 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Clear the DTCs.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| DTCs are output | B |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B