The cooler (room temp. sensor) thermistor is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the cooler (room temp. sensor) thermistor changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the cooler (room temp. sensor) thermistor and reads voltage changes due to changes in the resistance of the cooler (room temp. sensor) thermistor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1411 | Room Temperature Sensor Circuit | Any of the following conditions is met:
·
Open in cooler thermistor (room temperature sensor) circuit ·
Short in cooler thermistor (room temperature sensor) circuit |
·
Cooler (room temp. sensor) thermistor ·
Harness or connector between cooler (room temp. sensor) thermistor and air conditioning amplifier assembly ·
Air conditioning amplifier assembly |
Memorized
(4 seconds or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
If the cabin temperature is approximately -18.6°C (-1.48°F) or lower, DTC B1411 may be output even though the system is normal.
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | Ignition switch ON | ○ | ○ |
| Malfunction Status | Open in cooler thermistor (room temperature sensor) circuit | ○ | - |
| Short in cooler thermistor (room temperature sensor) circuit | - | ○ | |
| Detection Time | 4 seconds or more | 4 seconds or more | |
| Number of Trips | 1 trip | 1 trip | |
DTC will be output when conditions for either of the patterns in the table above are met.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler (room temp. sensor) thermistor | Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | - |
| Tester Display |
|---|
| Room Temperature Sensor |
The display is as specified in the normal condition column.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC) | C |
A
B
C
Remove the cooler (room temp. sensor) thermistor.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR>REMOVAL
Inspect the cooler (room temp. sensor) thermistor.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F71-14 (TR) - F60-1 | Always | Below 1 Ω |
| F71-1 (SG-1) - F60-2 | Always | Below 1 Ω |
| F71-14 (TR) or F60-1 - Body ground | Always | 10 kΩ or higher |
| F71-1 (SG-1) or F60-2 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Clear the DTCs.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| DTCs are output | B |
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING