HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System with Side-mounted Air Conditioner Pressure Sensor)  B14B8  Refrigerant Shortage  


DESCRIPTION

This DTC is stored if the amount of refrigerant in the air conditioning system is insufficient.

The air conditioning amplifier assembly receives the ambient temperature signal, refrigerant pressure signal, etc. from various sensors.

Based on these signals, the air conditioning amplifier assembly detects the amount of refrigerant.

The A/C switch indicator is turned off and the air conditioning system is stopped if the amount of refrigerant is insufficient.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B14B8 Refrigerant Shortage When following condition is detected in refrigerant shortage check in normal operation:
Amount of refrigerant is insufficient
·

Refrigerant pipe line

·

Cooler expansion valve

·

Air conditioning amplifier assembly


Memorized
(15 min. or more)*

*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.


WIRING DIAGRAM

E332460E18
2.125,0.406 2.583,0.667 0.458,0.26 10 false 3 2.135,0.896 2.594,1.156 0.458,0.26 10 false 2 2.125,1.354 2.583,1.615 0.458,0.26 10 false 1 1.917,0.51 2.375,0.771 0.458,0.26 10 false + 1.844,0.979 2.302,1.24 0.458,0.26 10 false PR 1.906,1.469 2.365,1.729 0.458,0.26 10 false - 0.417,2 1.438,2.281 1.021,0.281 10 false A22 0.406,2.146 2.531,2.458 2.125,0.313 10 false Air Conditioner Pressure Sensor 4.729,2 5.188,2.26 0.458,0.26 10 false F71 4.708,2.146 7.063,2.563 2.354,0.417 10 false Air Conditioning Amplifier Assembly 4.76,0.896 5.219,1.156 0.458,0.26 10 false 24 4.823,0.396 5.281,0.656 0.458,0.26 10 false 6 5.021,0.385 5.479,0.646 0.458,0.26 10 false S5-3 4.823,1.365 5.281,1.625 0.458,0.26 10 false 2 5.031,0.885 5.49,1.146 0.458,0.26 10 false PRE 5.021,1.354 5.479,1.615 0.458,0.26 10 false SG-2 6.479,0.958 6.938,1.219 0.458,0.26 10 false AD 5.885,0.323 6.344,0.583 0.458,0.26 10 false 5 V

PROCEDURE

1.CHECK REFRIGERANT PRESSURE
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
Actual refrigerant pressure displayed -
Body Electrical > Air Conditioner > Data List
Tester Display
Regulator Pressure Sensor
50003 121 52


g.

Read the manifold gauge pressure when the following conditions are met.

i.

Prepare the vehicle according to the table below.

Measurement Condition:
Item Condition
Vehicle doors Fully open
Temperature setting MAX COLD
Blower speed HI
A/C switch On
Recirculation/fresh switch RECIRCULATION
Interior temperature 25 to 35°C (77 to 95°F)



Standard Pressure:
Low pressure side:

150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)

High pressure side:

1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)


h.

Compare the values displayed in the Data List and on the manifold gauge.

OK:

The values displayed in the Data List and on the manifold gauge match.



Result:
Proceed to
OK
NG



OK

NG

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
2.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
a.

Disconnect the A22 air conditioner pressure sensor connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A22-3 (+) - A22-1 (-) Ignition switch to ON 4.75 to 5.25 V



Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - BODY GROUND)

NG

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - BODY GROUND)
a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A22-1 (-) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)

NG

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the F71 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A22-2 (PR) - F71-24 (PRE) Always Below 1 Ω
A22-2 (PR) or F71-24 (PRE) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

5.INSPECT AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Measure the voltage when the following conditions are met.

Measurement Condition:
Item Condition
Vehicle doors Fully open
Temperature setting MAX COLD
Blower speed HI
A/C switch On
Recirculation/fresh switch RECIRCULATION
Interior temperature 25 to 35°C (77 to 95°F)

NOTICE:
·

If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.

·

It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.



HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


i.
E328993C23
0.542,0.26 0.958,0.5 0.417,0.24 1.083,1.823 0.833,1.333 false 0.094,0.094 0.406,0.25 0.313,0.156 10 false *a 0.625,0.302 1.083,0.552 0.458,0.25 10 false F71 1.063,1.896 1.375,2.052 0.313,0.156 10 false PRE
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
F71-24 (PRE) - Body ground Ignition switch to ON
(A/C switch: On)
0.74 to 4.61 V




b.

Connect the GTS to the DLC3.


c.

Turn the ignition switch to ON.


d.

Turn the GTS on.


e.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


f.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
Actual refrigerant pressure displayed -
Body Electrical > Air Conditioner > Data List
Tester Display
Regulator Pressure Sensor
50003 121 52
OK:

The voltage and value displayed in the Data List change.



Result:
Result Proceed to
OK A
NG (The voltage changes but the value displayed in the Data List does not change)
NG (The voltage does not change) B



A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the F71 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A22-1 (-) - F71-2 (SG-2) Always Below 1 Ω
A22-1 (-) or F71-2 (SG-2) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the F71 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A22-3 (+) - F71-6 (S5-3) Always Below 1 Ω
A22-3 (+) or F71-6 (S5-3) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR