This DTC is stored if the amount of refrigerant in the air conditioning system is insufficient.
The air conditioning amplifier assembly receives the ambient temperature signal, refrigerant pressure signal, etc. from various sensors.
Based on these signals, the air conditioning amplifier assembly detects the amount of refrigerant.
The A/C switch indicator is turned off and the air conditioning system is stopped if the amount of refrigerant is insufficient.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B14B8 | Refrigerant Shortage | When following condition is detected in refrigerant shortage check in normal operation:
Amount of refrigerant is insufficient |
·
Refrigerant pipe line ·
Cooler expansion valve ·
Air conditioning amplifier assembly |
Memorized
(15 min. or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG
Max.: 3.2943 MPaG |
Actual refrigerant pressure displayed | - |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
for HFC-134a (R134a): Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFC-134a(R134a))>ON-VEHICLE INSPECTION
for HFO-1234yf (R1234yf): Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFO-1234yf(R1234yf))>ON-VEHICLE INSPECTION
Read the manifold gauge pressure when the following conditions are met.
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)
Compare the values displayed in the Data List and on the manifold gauge.
The values displayed in the Data List and on the manifold gauge match.
| Proceed to |
|---|
| OK |
| NG |
OK
for HFC-134a (R134a): Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFC-134a(R134a))>ON-VEHICLE INSPECTION
for HFO-1234yf (R1234yf): Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT(for HFO-1234yf(R1234yf))>ON-VEHICLE INSPECTION
NG
Disconnect the A22 air conditioner pressure sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-3 (+) - A22-1 (-) | Ignition switch to ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-1 (-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-2 (PR) - F71-24 (PRE) | Always | Below 1 Ω |
| A22-2 (PR) or F71-24 (PRE) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the voltage when the following conditions are met.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.
It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the thermistor assembly and the No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F71-24 (PRE) - Body ground | Ignition switch to ON
(A/C switch: On) |
0.74 to 4.61 V |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG
Max.: 3.2943 MPaG |
Actual refrigerant pressure displayed | - |
| Tester Display |
|---|
| Regulator Pressure Sensor |
The voltage and value displayed in the Data List change.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The voltage changes but the value displayed in the Data List does not change) | |
| NG (The voltage does not change) | B |
A
B
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-1 (-) - F71-2 (SG-2) | Always | Below 1 Ω |
| A22-1 (-) or F71-2 (SG-2) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F71 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A22-3 (+) - F71-6 (S5-3) | Always | Below 1 Ω |
| A22-3 (+) or F71-6 (S5-3) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG