ON-VEHICLE INSPECTION
Inspection · Vehicles built from Oct 2006
| INSPECT COOLING FAN ECU |
Inspect the input voltage.

Disconnect the cooling fan ECU connector.
Turn the ignition switch on (IG). Check the voltage of the +B1 terminal of the disconnected wire harness side connector.
- Standard voltage:
- 9 to 14 V
Inspect the cooling fan motor (Click here).
Disconnect ECM connector.
Measure the resistance between terminals RFC (ECM) and SI (cooling fan ECU) of the wire harness side connectors.
- HINT:
- If the fan does not operate, there may be a short circuit.
- If the fan remains operating, there may be an open circuit.
- If the fan does not operate, there may be a short circuit.
Inspect the ECM power source circuit and ground circuit.
Inspect the input signal and output current.

- NOTICE:
- Be sure to perform the inspection with the radiator coolant temperature less than 95°C (203 °F).
Connect the 400 A probe of the ammeter to terminal M+ of the cooling fan motor.
Set the intelligent tester to the oscilloscope function.
Using the intelligent tester, check the waveform between terminals RFC and E1 of the ECU.
- Standard waveform:
Condition
Input Signal
Output Current
Engine stopped
(Ignition switch on (IG))
Waveform 1
(Duty ratio 0%)
(Fan stops)
Engine idling
(A/C OFF)
Waveform 1
(0%)
(Fan stops)
Engine idling
(A/C ON)
Waveform 2
(30 to 70%)
2 to 11 A
(Fan operates)
Engine idling
(Coolant temperature sensor connector disconnected)
Waveform 3
(30 to 70%)
2 to 11 A
(Fan operates)
- HINT:
- If the input signal is abnormal, there is a malfunction in the ECM or cooling fan ECU.
- If the output current is abnormal even when the input signal is normal, there is a malfunction in the cooling fan ECU or motor.