B1830/57 Short in Driver Side Curtain Shield Squib Circuit
Diagnostic trouble codes · Vehicles built from Jun 2009
Also covers:
- B1831/57 Open in Driver Side Curtain Shield Squib Circuit
- B1832/57 Short to GND in Driver Side Curtain Shield Squib Circuit
- B1833/57 Short to B+ in Driver Side Curtain Shield Squib Circuit
Versions by build date: Jun 2006 – Sep 2006 Oct 2006 – May 2009 from Jun 2009
DESCRIPTION
The driver side curtain shield squib circuit consists of the center airbag sensor assembly and the curtain shield airbag assembly (driver side).The circuit instructs the SRS to deploy when deployment conditions are met.
These DTCs are recorded when a malfunction is detected in the driver side curtain shield squib circuit.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1830/57 |
|
|
| B1831/57 |
|
|
| B1832/57 |
|
|
| B1833/57 |
|
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Perform the simulation method by selecting the "check mode" (signal check) with the intelligent tester (Click here).
- After selecting the "check mode" (signal check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on a city or rough road (Click here).
- Perform the simulation method by selecting the "check mode" (signal check) with the intelligent tester (Click here).
| 1. CHECK CURTAIN SHIELD AIRBAG ASSEMBLY (DRIVER SIDE CURTAIN SHIELD SQUIB) |
Turn the ignition switch off.

Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connector from the curtain shield airbag assembly (driver side).
Connect the white wire side of SST (resistance 2.1 Ω) to connector C.
- CAUTION:
- Never connect a tester to the curtain shield airbag assembly (driver side curtain shield squib) for measurement, as this may lead to a serious injury due to airbag deployment.
- NOTICE:
- Do not forcibly insert the SST into the terminals of the connector when connecting.
- Insert straight the SST into the terminals of the connector.
- Do not forcibly insert the SST into the terminals of the connector when connecting.
- SST
- 09843-18060
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch off.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1830, B1831, B1832, B1833, or 57 is not output.
- HINT:
- Codes other than DTC B1830, B1831, B1832, B1833, and 57 may be output at this time, but they are not related to this check.
|
|
||||
| NG | |
| 2. CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the SST from connector C.
Check that the wire harness connector (on the curtain shield airbag assembly (driver side) side) is not damaged.
- OK:
- The lock button is not disengaged, or the claw of the lock is not deformed or damaged.
- Result:
Result
Proceed to
OK
A
NG (for LHD)
B
NG (for RHD)
C
|
|
||||
|
|
||||
| A | |
| 3. CHECK WIRE HARNESS (DRIVER SIDE CURTAIN SHIELD SQUIB CIRCUIT) |
Disconnect the connectors from the center airbag sensor assembly.

Check for a short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
- for LHD:
Tester connection
Condition
Specified condition
N21-1 (ICL+) - Body ground
Ignition switch on (IG)
Below 1 V
N21-2 (ICL-) - Body ground
Ignition switch on (IG)
Below 1 V
- for RHD:
Tester connection
Condition
Specified condition
O16-1 (ICR+) - Body ground
Ignition switch on (IG)
Below 1 V
O16-2 (ICR-) - Body ground
Ignition switch on (IG)
Below 1 V
- Result:
Result
Proceed to
OK
A
NG (for LHD)
B
NG (for RHD)
C
Check for an open in the circuit.
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
- for LHD:
Tester connection
Condition
Specified condition
N21-1 (ICL+) - N21-2 (ICL-)
Always
Below 1 Ω
- for RHD:
Tester connection
Condition
Specified condition
O16-1 (ICR+) - O16-2 (ICR-)
Always
Below 1 Ω
- Result:
Result
Proceed to
OK
A
NG (for LHD)
B
NG (for RHD)
C
Check for a short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
- for LHD:
Tester connection
Condition
Specified condition
N21-1 (ICL+) - Body ground
Always
1 MΩ or higher
N21-2 (ICL-) - Body ground
Always
1 MΩ or higher
- for RHD:
Tester connection
Condition
Specified condition
O16-1 (ICR+) - Body ground
Always
1 MΩ or higher
O16-2 (ICR-) - Body ground
Always
1 MΩ or higher
- Result:
Result
Proceed to
OK
A
NG (for LHD)
B
NG (for RHD)
C
Check for a short in the circuit.
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
- for LHD:
Tester connection
Condition
Specified condition
N21-1 (ICL+) - N21-2 (ICL-)
Always
1 MΩ or higher
- for LHD:
Tester connection
Condition
Specified condition
O16-1 (ICR+) - O16-2 (ICR-)
Always
1 MΩ or higher
- Result:
Result
Proceed to
OK
A
NG (for LHD)
B
NG (for RHD)
C
|
|
||||
|
|
||||
| A | |
| 4. CHECK CENTER AIRBAG SENSOR ASSEMBLY |
Connect the connectors to the curtain shield airbag assembly (driver side) and the center airbag sensor assembly.

Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch off.
Turn the ignition switch on (IG), and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1830, B1831, B1832, B1833, or 57 is not output.
- HINT:
- Codes other than DTC B1830, B1831, B1832, B1833, and 57 may be output at this time, but they are not related to this check.
- Result:
Result
Proceed to
OK
A
NG (for 2GR-FE RHD)
B
NG (except 2GR-FE RHD)
C
|
|
||||
|
|
||||
| A | ||
| ||