C1249/49 Open in Stop Light Switch Circuit
Diagnostic trouble codes · Vehicles built Jun 2006 – Sep 2006
Versions by build date: Jun 2006 – Sep 2006 Oct 2006 – May 2009 from Jun 2009
DESCRIPTION
This circuit recognizes brake operation by sending a stop light signal to the skid control ECU.The skid control ECU has an open detection circuit, which outputs this DTC when detecting an open in the stop light signal input line (STP terminal) or the ground line of the stop light circuit with the stop light switch off (brake pedal not depressed).
| DTC No. |
DTC Detection Condition |
Trouble Area |
| C1249/49 |
When either of the following is detected:
|
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Check the condition of each related circuit connector before troubleshooting (Click here).
| 1. CHECK STOP LIGHT SWITCH OPERATION (STOP LIGHT SWITCH CIRCUIT) |
Check that the stop lights come on when the brake pedal is depressed and go off when the brake pedal is released.
- OK:
Pedal Condition
Illumination Condition
Brake pedal depressed
ON
Brake pedal released
OFF
|
|
||||
| OK | |
| 2. INSPECT SKID CONTROL ECU (STP TERMINAL) |
Disconnect the skid control ECU connector.

Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Switch Condition
Specified Condition
A26-30 (STP1) - Body ground
Brake pedal depressed
8 to 14 V
A26-30 (STP1) - Body ground
Brake pedal released
Below 4.0 V
|
|
||||
| OK | |
| 3. INSPECT SKID CONTROL ECU (GND TERMINAL CONTINUITY) |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Specified Condition
A26-4 (GND1) - Body ground
Below 1 Ω
A26-1 (GND2) - Body ground
Below 1 Ω
Connect the connector.
|
|
||||
| OK | |
| 4. RECONFIRM DTC |
Clear the DTCs (Click here).
Start the engine.
Depress the brake pedal several times to test the stop light circuit.
Check if the same DTC is recorded (Click here).
- HINT:
- Reinstall the sensors, connectors, etc. and restore the vehicle to its prior condition before rechecking for DTCs.
- Result:
Result
Proceed to
DTC is not output
A
DTC is output (When troubleshooting in accordance with the DTC CHART)
B
DTC is not output (When troubleshooting in accordance with the PROBLEM SYMPTOMS TABLE)
C
- HINT:
- It is suspected that the DTCs were output due to a bad connection of the connector terminal.
|
|
||||
|
|
||||
| A | ||
| ||
| 5. CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH POWER SOURCE TERMINAL VOLTAGE) |
Disconnect the stop light switch connector.

Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
A19-2 - Body ground
Always
10 to 14 V
|
|
||||
| OK | |
| 6. INSPECT STOP LIGHT SWITCH ASSEMBLY |
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Switch Condition
Specified Condition
1 - 2
Switch pin free
Below 1 Ω
1 - 2
Switch pin pushed in
10 kΩ or higher
Connect the connector.
|
|
||||
| OK | |
| 7. CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH TO SKID CONTROL ECU) |
Disconnect the stop light switch connector and skid control ECU connector.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
A26-30 (STP1) - A19-1
Below 1 Ω
Connect the connectors.
|
|
||||
| OK | ||
| ||