2006-2011 Camry Aurion · Service Manual HEATER & AIR CONDITIONING SYSTEM

Back-up Power Source Circuit

Circuit diagnosis · Vehicles built from Jun 2006

DESCRIPTION

The back-up power source circuit for the A/C amplifier is shown below. Power is supplied even when turning the ignition switch to the LOCK position and is used for diagnostic trouble code memory, etc.

WIRING DIAGRAM

E116884E03

INSPECTION PROCEDURE


1. INSPECT FUSE (A/C)

  1. E124481E03
    Remove the A/C fuse from the instrument panel J/B.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Item
    Condition
    Specified Condition
    A/C fuse
    Always
    Below 1 Ω



NG
REPLACE FUSE (A/C)
OK


2. INSPECT AIR CONDITIONING AMPLIFIER (AIR CONDITIONING AMPLIFIER - BODY GROUND)

  1. E124470E16
    Disconnect the A/C amplifier connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    E38-21 (B) - Body ground
    Always
    10 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE