INSPECTION
Inspection · Vehicles built from Jun 2006
| INSPECT POWER WINDOW MASTER SWITCH (w/ Jam Protection Function) |
Measure the resistance when the switch is operated according to the value(s) in the table below.

- Standard resistance:
- LHD models:
Tester Connection
Switch Condition
Specified Condition
8 (U) - 1 (E) - 4 (A)
Auto UP
Below 1 Ω
8 (U) - 1 (E)
Manual UP
Below 1 Ω
8 (U) - 5 (D) - 6 (B)
OFF
Below 1 Ω
5 (D) - 1 (E)
Manual DOWN
Below 1 Ω
8 (U) - 6 (B)
Below 1 Ω
4 (A) - 5 (D) - 1 (E)
Auto DOWN
Below 1 Ω
1 (E) - 10 (U)
Lock/Unlock switch
UNLOCK (Below 1 Ω) → LOCK (10 kΩ or higher)
1 (E) - 12 (U)
1 (E) - 13 (D)
1 (E) - 15 (D)
1 (E) - 16 (U)
1 (E) - 18 (D)
- RHD models:
Tester Connection
Switch Condition
Specified Condition
1 (U) - 9 (E) - 4 (A)
Auto UP
Below 1 Ω
1 (U) - 9 (E)
Manual UP
Below 1 Ω
1 (U) - 5 (D) - 6 (B)
OFF
Below 1 Ω
5 (D) - 9 (E)
Manual DOWN
Below 1 Ω
1 (U) - 6 (B)
Below 1 Ω
4 (A) - 5 (D) - 9 (E)
Auto DOWN
Below 1 Ω
9 (E) - 16 (U)
Lock/Unlock switch
UNLOCK (Below 1 Ω) → LOCK (10 kΩ or higher)
9 (E) - 18 (U)
9 (E) - 10 (D)
9 (E) - 13 (D)
9 (E) - 12 (U)
9 (E) - 15 (D)
| INSPECT POWER WINDOW MASTER SWITCH (w/o Jam Protection Function) |
Measure the resistance when the switch is operated according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Switch Condition
Specified Condition
1 (E) - 3 (U)
OFF
Below 1 Ω
1 (E) - 4 (D)
Below 1 Ω
1 (E) - 10 (U)
Lock/Unlock switch
UNLOCK (Below 1 Ω) → LOCK (10 kΩ or higher)
1 (E) - 12 (U)
1 (E) - 13 (D)
1 (E) - 15 (D)
1 (E) - 16 (U)
1 (E) - 18 (D)