Driver Side Power Window Motor Circuit
Circuit diagnosis · Vehicles built from Jun 2006
DESCRIPTION
This circuit transmits signals from the power window regulator master switch assembly to the power window regulator motor (Driver side).WIRING DIAGRAM




INSPECTION PROCEDURE
| 1. INSPECT POWER WINDOW REGULATOR MOTOR |
without Jam protection:Remove the power window motor.

Apply battery voltage to the motor connector according to the table below.
- NOTICE:
- Do not apply battery voltage to any terminals except terminals 1and 2.
- OK:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
Motor gear rotates clockwise
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Motor gear rotates counterclockwise
Remove the power window motor.

Apply battery voltage to the motor connector according to the table below.
- NOTICE:
- Do not apply battery voltage to any terminals except terminals 1, 2, 4, 7 and 10.
- OK:
Switch Condition
Measurement Condition
Specified Condition
Manual Operation
Battery positive (+) → Terminal 2 (B)
Battery negative (-) → Terminal 1 (E), 7 (DWN1)
Motor gear rotates counterclockwise
Battery positive (+) → Terminal 2 (B)
Battery negative (-) → Terminal 1 (E), 10 (UP1)
Motor gear rotates clockwise
Auto Operation
Battery positive (+) → Terminal 2 (B)
Battery negative (-) → Terminal 1 (E), 4 (AUTO), 7 (DWN1)
Motor gear rotates counterclockwise
Battery positive (+) → Terminal 2 (B)
Battery negative (-) → Terminal 1 (E), 4 (AUTO), 10 (UP1)
Motor gear rotates clockwise
|
|
||||
| OK | |
| 2. CHECK WIRE HARNESS (WINDOW REGULATOR MOTOR - WINDOW REGULATOR MASTER SWITCH) |
without Jam protection:Disconnect the M1 and I4 connectors.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
M1-3 (U) - I4-2
Always
Below 1 Ω
M1-4 (D) - I4-1
Always
Below 1 Ω
M1-3 (U) - Body ground
Always
10 kΩ or higher
M1-4 (D) - Body ground
Always
10 kΩ or higher
with Jam protection:Disconnect the M1 (*1), L1 (*2) and I5 (*1), H10 (*2) connectors.

- HINT:
- *1: LHD models
- *2: RHD models
- *1: LHD models
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
- LHD models:
Tester Connection
Condition
Specified Condition
M1-8 (U) - I5-10 (UP1)
Always
Below 1 Ω
M1-5 (D) - I5-7 (DWN1)
Always
Below 1 Ω
M1-8 (U) - Body ground
Always
10 kΩ or higher
M1-5 (D) - Body ground
Always
10 kΩ or higher
- RHD models:
Tester Connection
Condition
Specified Condition
L1-1 (U) - H10-10 (UP1)
Always
Below 1 Ω
L1-5 (D) - H10-7 (DWN1)
Always
Below 1 Ω
L1-1 (U) - Body ground
Always
10 kΩ or higher
L1-5 (D) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||