FAIL-SAFE CHART
System information · Vehicles built from Oct 2006
Versions by build date: Jun 2006 – Sep 2006 from Oct 2006
| Condition |
Response |
Recovery |
| Engine coolant temperature data is interrupted for 3.1 seconds. |
The gauge needle indicates C (COOL). |
Engine coolant temperature data is received. |
| Condition |
Response |
Recovery |
| Shift position data is interrupted for 3.1 seconds. |
All indicator light (LCD) go off. |
Normal data is received. |
| Condition |
Response |
Recovery |
| ABS, BA, TRC and VSC data is interrupted for 1 second. |
The warning light comes on. |
Normal data is received. |
| Condition |
Response |
Recovery |
| Each door condition data is interrupted for 10 seconds. |
The data received most recently remains indicated. |
Normal data is received. |
| Condition |
Response |
Recovery |
| Driver side front seat inner belt assembly data is interrupted for 10 seconds. |
The data received most recently remains indicated. |
Normal data is received. |
| Condition |
Response |
Recovery |
| Regular data is interrupted for 10 seconds. |
The data received most recently remains indicated. |
Normal data is received. |
| Condition |
Response |
Recovery |
| Airbag data is interrupted for 10 seconds when the combination meter (meter CPU) detect the voltage of 9 V or more. |
The warning light comes on. |
Normal data is received. |
| Ignition switch on (IG), then the combination meter (meter CPU) cannot detect the voltage of 9 V or less for 60 seconds. |
| Condition |
Response |
Recovery |
| Regular data is interrupted for 10 seconds. |
The data received most recently remains indicated. |
Normal data is received. |
| Condition |
Response |
Recovery |
| Regular data is interrupted for 10 seconds. |
The data received most recently remains indicated. |
Normal data is received. |
| Condition |
Response |
Recovery |
| Outside temperature data is interrupted for 10 seconds. |
The display indicates "E". |
Normal data is received. |
| Abnormal outside temperature data is received. |
The display indicates "E°C"/"--°C"/"°C". |
Normal data is received. |
| Cruise information data is interrupted for 60 seconds. |
The display becomes blank (only measurement units are displayed). |
Normal data is received. |
*2: with VSC
*3: with Cruise Control System
*4: with Multi-information Display