Entire Combination Meter does not Operate
Circuit diagnosis · Vehicles built from Oct 2006
Versions by build date: Jun 2006 – Sep 2006 from Oct 2006
DESCRIPTION
This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is a power source mainly used for signal transmission. The constant power source is mainly used as a backup power source of the meter CPU, however, it is also used for communication. If a voltage of 12 V is not applied to terminal IG+ when turn the ignition switch on (IG), the indicator will not operate.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT COMBINATION METER ASSEMBLY |
for 2AZ-FE:

Disconnect the F1 connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
F1-12 (E2) - Body ground
Always
Below 1 Ω
F1-24 (ES) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
F1-1 (B) - Body ground
Always
10 to 14 V
F1-2 (B2) - Body ground
Always
10 to 14 V
F1-13 (IG+) - Body ground
Ignition switch on (IG)
10 to 14 V
for 2GR-FE:

Disconnect the F1 connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
F1-12 (E2) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
F1-1 (B) - Body ground
Always
10 to 14 V
F1-2 (B2) - Body ground
Always
10 to 14 V
F1-13 (IG+) - Body ground
Ignition switch on (IG)
10 to 14 V
|
|
||||
| OK | ||
| ||