2006-2011 Camry Aurion · Service Manual BODY ELECTRICAL

Entire Combination Meter does not Operate

Circuit diagnosis · Vehicles built Jun 2006 – Sep 2006

Versions by build date: Jun 2006 – Sep 2006 from Oct 2006

DESCRIPTION

This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is a power source mainly used for signal transmission. The constant power source is mainly used as a backup power source of the meter CPU, however, it is also used for communication. If a voltage of 12 V is not applied to terminal IG+ when turning the ignition switch to the ON position, the indicator will not operate.

WIRING DIAGRAM

E136506E01

INSPECTION PROCEDURE


1. INSPECT COMBINATION METER ASSEMBLY

  1. E134491E01
    Disconnect the F1 connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    F1-12 (E2) - Body ground
    Always
    Below 1 Ω
    F1-24 (ES) - Body ground
    Always
    Below 1 Ω

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    F1-1 (B) - Body ground
    Always
    10 to 14 V
    F1-2 (B2) - Body ground
    Always
    10 to 14 V
    F1-13 (IG+) - Body ground
    Turn the ignition switch to the ON position
    10 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY