2006-2011 Camry Aurion · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built from Jun 2006


INSPECT AIR FUEL RATIO SENSOR

  1. A075325E13
    Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (HA1A) - 2 (+B)
    20°C (68°F)
    1.8 to 3.4 Ω
    1 (HA1A) - 4 (A1A-)
    Always
    10 kΩ or higher

    If the result is not as specified, replace the sensor.

← REMOVAL (from Jun 2006)INSTALLATION (Jun 2006 – Sep 2006) →