2006-2011 Camry Aurion · Service Manual BODY ELECTRICAL

INSPECTION

Inspection · Vehicles built from Oct 2006


INSPECT ENTRY LOCK SWITCH

  1. B112465E18
    Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    for Front LH Side:
    Tester Connection (Symbols)
    Condition
    Specified Condition
    X1-1 (TRG-) - X1-3 (TRG+)
    Lock switch not pushed
    10 kΩ or higher
    Lock switch pushed
    Below 1 Ω
    for Front RH Side:
    Tester Connection (Symbols)
    Condition
    Specified Condition
    W1-1 (TRG-) - W1-3 (TRG+)
    Lock switch not pushed
    10 kΩ or higher
    Lock switch pushed
    Below 1 Ω

    If the result is not specified, replace the entry lock switch.

← REMOVAL (from Jun 2009)INSTALLATION (Oct 2006 – May 2009) →