P2810 Pressure Control Solenoid "G" Electrical (Shift Solenoid Valve SL4)
Diagnostic trouble codes · Vehicles built from Oct 2006
DESCRIPTION
Shifting gears from 1st through 5th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, SL3 and SL4 which are controlled by the TCM. If an open or short circuit occurs in either of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (Fail safe function).| DTC No. |
DTC Detection Condition |
Trouble Area |
| P2810 |
The TCM checks for an open or short in the shift solenoid valve SL4 circuit while driving and shifting gears. (1-trip detection logic)
|
|
MONITOR DESCRIPTION
The TCM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. And the TCM performs the fail-safe function and turns the other normal shift solenoid valves on or off. (In case of an open or short circuit, the TCM stops sending current to the circuit.)(Click here)
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SL4 CIRCUIT) |
Remove the TCM from the transaxle.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
22 (SL4+) - 21 (SL4-)
5.0 to 5.6 Ω
(at 20°C (68°F))
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
22 (SL4+) - Body ground
10 kΩ or higher
21 (SL4-) - Body ground
10 kΩ or higher
|
|
||||
| NG | |
| 2. INSPECT SHIFT SOLENOID VALVE SL4 |
Remove the shift solenoid valve SL4.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Specified Condition
1 - 2
5.0 to 5.6 Ω
(at 20°C (68°F))
Connect a positive (+) lead through a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes an operating sound.
|
|
||||
| OK | ||
| ||