INSPECTION
Inspection · Vehicles built from Oct 2006
| INSPECT SHIFT SOLENOID VALVE SL |
Measure the resistance according to the value(s) in the table below.

If the value is not as specified, replace the shift solenoid valve.Standard resistance Tester Connection
Specified Condition
20°C (68°F)
Solenoid Connector (SL) - Solenoid Body (SL)
11 to 15 Ω
Connect the positive (+) lead to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

- OK:
- The solenoid makes an operating noise.
| INSPECT SHIFT SOLENOID VALVE SLT |
Measure the resistance according to the value(s) in the table below.

If the value is not as specified, replace the shift solenoid valve.Standard resistance Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
- OK:
- The solenoid makes an operating noise.
| INSPECT SHIFT SOLENOID VALVE SLU |
Measure the resistance according to the value(s) in the table below.

If the value is not as specified, replace the shift solenoid valve.Standard resistance Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
- OK:
- The solenoid makes an operating noise.
| INSPECT SHIFT SOLENOID VALVE SL2 |
Measure the resistance according to the value(s) in the table below.

If the value is not as specified, replace the shift solenoid valve.Standard resistance Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
- OK:
- The solenoid makes an operating noise.
| INSPECT SHIFT SOLENOID VALVE SL1 |
Measure the resistance according to the value(s) in the table below.

If the value is not as specified, replace the shift solenoid valve.Standard resistance Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
- OK:
- The solenoid makes an operating noise.
| INSPECT SHIFT SOLENOID VALVE SL3 |
Measure the resistance according to the value(s) in the table below.

If the value is not as specified, replace the shift solenoid valve.Standard resistance Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
- OK:
- The solenoid makes an operating noise.
| INSPECT SHIFT SOLENOID VALVE SL4 |
Measure the resistance according to the value(s) in the table below.

If the value is not as specified, replace the shift solenoid valve.Standard resistance Tester Connection
Specified Condition
20°C (68°F)
1 - 2
5.0 to 5.6 Ω
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.
- OK:
- The solenoid makes an operating noise.
