Home › BODY › WINDSHIELD / WINDOWGLASS › POWER WINDOW CONTROL SYSTEM (for Models with Jam Protection Function on 4 Windows)

POWER WINDOW CONTROL SYSTEM (for Models with Jam Protection Function on 4 Windows) > Driver Side Power Window does not Operate with Power Window Master Switch

for Preparation Click here


DESCRIPTION

When the engine is running or the ignition switch is ON, the power window regulator motor assembly (for driver side) is operated by the power window regulator master switch assembly. The power window regulator motor assembly (for driver side) has motor, regulator, and ECU functions.

HINT:
If the pulse sensor built into the power window regulator motor assembly (for driver side) malfunctions, the power window control system enters fail-safe mode. The remote up/down and auto up/down functions cannot be operated during fail-safe mode. However, the power window can be closed by holding the power window regulator master switch assembly at the auto up position, and opened manually by pushing down the power window regulator master switch assembly.


WIRING DIAGRAM


B219096E07


INSPECTION PROCEDURE

NOTICE:
  1. The power window control system uses a multiplex communication system (LIN communication system). Inspect the communication function by following How to Proceed with Troubleshooting (Click here). Troubleshoot the power window control system after confirming that the communication system is functioning properly.
  2. When the power window regulator motor assembly (for driver side) is reinstalled or replaced, the power window control system must be initialized.
  3. After a door glass or a door glass run has been replaced, the jam protection function may operate unexpectedly when the auto up function is used. In such cases, the auto up function can be reinitialized by repeating the following operations at least 5 times:
    1. Close the power window by fully pulling up the power window regulator master switch assembly and holding it at the auto up position.
    2. Open the power window by fully pushing down the power window regulator master switch assembly.
  4. When the ECU determines that the power window regulator motor assembly (for driver side) has a malfunction, DTC B2311 is set.

1.READ VALUE USING INTELLIGENT TESTER (Main Body)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the intelligent tester on.

  1. Enter the following menus: Body / Main Body / Data List.

  1. Read the Data List according to the display on the intelligent tester.

    Main Body (Main Body ECU (Instrument Panel J/B)) 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Communication D-Door Motor
    Connection status between power window regulator motor (for driver side) and main body ECU (instrument panel J/B) / OK or STOP
    OK: Normal communication
    STOP: Communication stopped
    -

    OK:
    On the intelligent tester screen, OK is displayed.



NG
GO TO LIN COMMUNICATION SYSTEM (Proceed to How to Proceed with Troubleshooting) (Click here)
OK


2.READ VALUE USING INTELLIGENT TESTER (D-Door Motor)
  1. Enter the following menus: Body / D-Door Motor / Data List.

  1. Read the Data List according to the display on the intelligent tester.

    D-Door Motor (Power Window Regulator Motor Assembly (for Driver Side)) 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    D Door P/W Up SW
    Driver side power window manual up switch signal / ON or OFF
    ON: Driver door power window manual up switch operated
    OFF: Driver door power window manual up switch not operated
    -
    D Door P/W Down SW
    Driver side power window manual down switch signal / ON or OFF
    ON: Driver door power window manual down switch operated
    OFF: Driver door power window manual down switch not operated
    -

    OK:
    On the intelligent tester screen, ON or OFF is displayed accordingly.



NG
Go to step 4
OK


3.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (D-Door Motor)
  1. Enter the following menus: Body / D-Door Motor / Active Test.

  1. Perform the Active Test according to the display on the intelligent tester.

    D-Door Motor (Power Window Regulator Motor Assembly (for Driver Side)) 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Power Window
    Power window
    OFF / UP / DOWN
    -

    OK:
    Driver side power window operates normally.

    CAUTION:
    Be careful to avoid injuries as this test causes vehicle parts to move. During the Active Test, the jam protection function will not operate.



NG
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Driver Side) (Click here)
OK

REPLACE MAIN BODY ECU (INSTRUMENT PANEL J/B) 

4.CHECK HARNESS AND CONNECTOR (MASTER SWITCH - DRIVER SIDE MOTOR)
B193520E08
  1. Disconnect the power window regulator master switch assembly connector.

  1. Disconnect the power window regulator motor assembly (for driver side) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    M2-20 (UP) - I5-10 (UP)
    Always
    Below 1 Ω
    M2-15 (DOWN) - I5-7 (DOWN)
    Always
    Below 1 Ω
    M2-20 (UP) - Body ground
    Always
    10 kΩ or higher
    M2-15 (DOWN) - Body ground
    Always
    10 kΩ or higher
    I5-10 (UP) - Body ground
    Always
    10 kΩ or higher
    I5-7 (DOWN) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
  1. Replace the power window regulator master switch assembly (Click here).


NEXT


6.CHECK MANUAL UP / DOWN FUNCTION (for Driver Side)
  1. Check that the driver side door power window moves when the manual up/down function of the power window regulator master switch assembly is operated (Click here).

OK:
Driver side manual up/down function is normal.



NG
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (for Driver Side) (Click here)
OK

END (POWER WINDOW REGULATOR MASTER SWITCH WAS DEFECTIVE)