METER / GAUGE SYSTEM > Fuel Receiver Gauge Malfunction |

| 1.CHECK CAN COMMUNICATION SYSTEM |
Check if CAN communication DTC is output (Click herefor LHD, Click here for RHD).
| Result | Proceed to |
| CAN communication DTC is not output | A |
| CAN communication DTC is output | B (Click herefor LHD, Click here for RHD) |
|
| ||||
| A | |
| 2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Turn the tester ON.
Enter following menus: Diagnosis / OBD/MOBD / Combination Meter / Active Test.
Check the operation by referring to the table below.
| Tester Display | Test Part | Control Range | Normal Condition |
| Fuel Meter Operation | Fuel receiver gauge | EMPTY, 1/2, FULL | - |
|
| ||||
| OK | |
| 3.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Turn the tester ON.
Enter following menus: Diagnosis / OBD/MOBD / Combination Meter / Data List.
Check the values by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Fuel Input | Fuel input signal Min.: 0, Max.: 255 | Fuel gauge indicates (F): 35 Fuel gauge indicates (3/4): 85 Fuel gauge indicates (1/2): 145 Fuel gauge indicates (3/4): 186 Fuel gauge indicates (E): 205 | - |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (COMBINATION METER - FUEL SENDER GAUGE ASSEMBLY) |
![]() |
Disconnect the F2 and N10 connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| F2-15 (FR) - N10-2 | Always | Below 1 Ω |
| F2-16 (FE) - N10-3 | Always | Below 1 Ω |
| N10-2 - Body ground | Always | 10 kΩ or higher |
| F2-16 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 5.INSPECT FUEL SENDER GAUGE ASSEMBLY |
![]() |
Disconnect the fuel sender gauge connector.
Remove the fuel sender gauge assembly.
Check that the float moves smoothly between F and E.
Measure the resistance between the terminals 2 (S) and 3 (FE) of connector according to the value(s) in the table below.
| Float Level | Resistance (Ω) |
| F | 13.5 to 16.5 |
| Between E and F | 13.5 to 414.5 (Gradually changes) |
| E | 405.5 to 414.5 |
|
| ||||
| OK | |
| 6.REPLACE COMBINATION METER ASSEMBLY |
Replace the combination meter assembly with a new one or a normal one.
|
| ||||
| OK | ||
| ||