DTC B2272 Ignition 1 Monitor Malfunction |
| DTC No. | DTC Detection Condition | Trouble Area |
| B2272 | IG1 relay actuation circuit inside main body ECU or other related circuit is malfunctioning |
|

| 1.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Body / Data List.
Read the Data List according to the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| IG1 Relay Mon 1 | Status of IG1 relay monitor (outer) / ON or OFF | ON: Engine switch on (IG) (IG1 relay is ON) OFF: Engine switch off (IG1 relay is OFF) | - |
|
| ||||
| OK | |
| 2.CHECK ENGINE SWITCH CONDITION |
Check the power source mode change.
When the key is inside the vehicle and the shift lever is in the P position, check that pressing the engine switch causes the power source mode to change as follows:
|
| ||||
| OK | |
| 3.INSPECT RELAY (IG1 RELAY) |
![]() |
Remove the IG1 relay from the instrument panel J/B.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | When battery voltage is not applied terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | When battery voltage is applied terminals 1 and 2 | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK WIRE HARNESS (INSTRUMENT PANEL J/B - MAIN BODY ECU) |
Disconnect the Il J/B connector.

Disconnect the E7 ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| II-9 - E7-3 (IG1D) | Always | Below 1 Ω |
| E7-3 (IG1D) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 5.CHECK WIRE HARNESS (INSTRUMENT PANEL J/B - BATTERY AND BODY GROUND) |
![]() |
Disconnect the IF and IA J/B connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified value |
| IF-10 - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified value |
| IA-1 - Body ground | Always | 11 to 14 V |
|
| ||||
| OK | |
| 6.INSPECT INSTRUMENT PANEL J/B |
Measure the resistance according to the value(s) in the table below.

| Tester Connection | Condition | Specified value |
| IF-10 - IG1 relay terminal-1 | Always | Below 1 Ω |
| Il-9 - IG1 relay terminal-2 | Always | Below 1 Ω |
| IF-10 - Body ground | Always | 10 kΩ or higher |
| Il-9 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||